0 troubleshooting – Hall Research SC-12BT User Manual

Page 12

Advertising
background image

Multi-Format Scaler Switch with HDBaseT

12

Command

Response

Notes

R Keylock

R Keylock X

Get Current Keylock Status X = 0,1,2,3

S IP X

S IP X

X = VALID IP address.

S SB X

S SB X

X = VALID Subnet Address

S GW X

S GW X

X = VALID Gateway Address

S DHCP 1

S DHCP 1

Enable DHCP

S DHCP 0

S DHCP 0

Disable DHCP

R Ipconfig

IP X

DHCP Y

X = Current IP address of the Unit.

Y = Current DHCP status (1 = Enabled , 0 = Disabled)

6.0 Troubleshooting

If you are experiencing problems getting the scaler to work properly, please

use the following troubleshooting suggestions.

o Make sure the power LED is lit on the front panel. If not check power

connection and ensure that all of the connections between sources and

outputs are firmly secured. Loose connections are the number one cause

of issues.

o Select other inputs, and try changing the output resolution.
o Power cycle the system by unplugging the power supply connected to the

scaler, waiting 5 seconds and plugging it back in.

o If a specific source is not working, verify that the source works when

directly connected to the output display.

o The command “S Reset 1” can be sent to the scaler in order to initiate a

factory reset. Please be advised that this command will reset all settings

on the scaler back to factory default (and set IP config to DHCP).

o If you are experiencing issues with the HDBaseT output of the unit, make

sure that the twisted-pair cable meets the system requirements and check

the length. Try using a short cable as a test. Be advised that the HDBaseT

output of this unit is Lite™ (Class B) rated for up to 230ft (70m) at 1080p,

and it does not support IR, RS-232, or PoH (power over HDBaseT)

extension.

If you are still not able to get the system working properly, contact Hall

Research support (preferably via email or the form on support page of

www.hallresearch .com) with a detailed description of the issue and the

troubleshooting steps you have taken.

Do not open or try to repair the unit yourself as this will void your warranty.

To return the extender for repair, you must contact HR Support at 714-641-

6607, via email, or on our website. To ship the unit back for repair, make sure

to obtain a Return Material Authorization (RMA) number.