ELECTRODES
HI 1048B

Glass body, double junction, refillable pH electrode with
BNC connector and 1 m (3.3') cable, for wine, must and
grape juice

FC 100B

PVDF

body, double junction, refillable, pH electrode with

BNC connector and 1 m (3.3') cable, for food industry

FC 200B

PVDF

body, open junction, conic tip, Viscolene, non-refillable

pH electrode with BNC connector and 1 m (3.3') cable, for
meat & cheese

FC 210B

Glass body, double junction, conic tip, Viscolene, non-
refillable pH electrode with BNC connector and 1 m (3.3')
cable, for milk and yogurt

HI 3131B

Glass body, refillable, platinum ORP electrode

HI 3230B

Plastic body, gel-filled, platinum ORP electrode

HI 4430B

Plastic body, gel-filled, gold ORP electrode

OTHER ACCESSORIES
HI 710005

115 Vac/12 Vdc power adapter, US plug

HI 710006

230 Vac/12 Vdc power adapter, European plug

HI 76405

Electrode holder

HI 8427

pH and ORP electrode simulator with 1 m (3.3') coaxial
cable ending in female BNC connectors

HI 931001

pH and ORP electrode simulator with LCD and 1 m (3.3')
coaxial cable ending in female BNC connectors

HI 98501

Pocket-size thermometer (range -50.0 to 150.0°C)

Recommendations for Users

Before using this product, make sure that it is entirely suitable for the environment in which it is used.

Operation of this instrument in residential area could cause unacceptable interferences to radio and TV equipment, requiring the
operator to take all necessary steps to correct interferences.

The glass bulb at the end of the electrode is sensitive to electrostatic discharges. Avoid touching this glass bulb at all times.
During calibration of instruments, ESD wrist straps should be worn to avoid possible damage to the electrode by electrostatic
discharge.

To maintain the EMC performance of this equipment, the recommended cables noted in the user's manual must be used.
Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance.

To avoid electrical shock, do not use this instrument when voltages at the measurement surface exceed 24 Vac or 60 Vdc.

To avoid damage or burns, do not perform any measurement in microwave ovens.

WARRANTY

All Hanna Instruments meters are guaranteed for two years against defects
in workmanship and materials when used for their intended purpose and
maintained according to instructions.
Electrodes and probes are guaranteed for a period of six months.
This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed maintenance
are not covered.
If service is required, contact the dealer from whom you purchased the
instrument. If under warranty, report the model number, date of purchase,
serial number and the nature of the failure. If the repair is not covered by the
warranty, you will be notified of the charges incurred. If the instrument is to be
returned to Hanna Instruments, first obtain a Returned Goods Authorization
number from the Customer Service department and then send it with shipping
costs prepaid. When shipping any instrument, make sure it is properly
packaged for complete protection.

All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner.

Hanna Instruments reserves the right to modify the design, construction and

appearance of its products without advance notice.