Hanna Instruments HI 4105 User Manual
Page 10

18
19
XV.
XV.
XV.
XV.
XV. Storage and Care of the HI 4105 sensor
Storage and Care of the HI 4105 sensor
Storage and Care of the HI 4105 sensor
Storage and Care of the HI 4105 sensor
Storage and Care of the HI 4105 sensor
The HI 4105 sensor can be stored assembled and ready to
use in HI 4005-45 Conditioning solution overnight or
between measurements. After overnight storage, gently pull
on the cable to compress the spring mechanism thus
permitting electrolyte to exchange from the bulk to the thin
film between the membrane and glass. Calibration is
required after doing this.
For longer term storage (over a week), disassemble the
sensor completely and rinse off the internal pH/reference
assembly, the outer body and the membrane cap. It is
advised the membrane cap be discarded to prevent pos-
sible problems associated with reuse. Cover the glass tip
with the protective shipping cap and store parts securely in
the original shipping box. When reassembling the sensor
follow section IX.
XVI.
XVI.
XVI.
XVI.
XVI. Conversion T
Conversion T
Conversion T
Conversion T
Conversion Tables
ables
ables
ables
ables
For CO
For CO
For CO
For CO
For CO
22222
Multiply by
Multiply by
Multiply by
Multiply by
Multiply by
Moles/L (M) CO
2
to ppm CO
2
(mg/L)
4.4 X 10
4
ppm CO
2
(mg/L) to M (Moles/L)
2.273 X 10
-3
For CaCO
For CaCO
For CaCO
For CaCO
For CaCO
3
3
3
3
3
(ppm)
(ppm)
(ppm)
(ppm)
(ppm)
Multiply by
Multiply by
Multiply by
Multiply by
Multiply by
Moles/L (M) CO
2
to ppm CaCO
3
(mg/L)
1.00 X 10
5
XVII.
XVII.
XVII.
XVII.
XVII. HI 4105 A
HI 4105 A
HI 4105 A
HI 4105 A
HI 4105 Accessories and Replacement P
ccessories and Replacement P
ccessories and Replacement P
ccessories and Replacement P
ccessories and Replacement Parts
arts
arts
arts
arts
For Calibration
For Calibration
For Calibration
For Calibration
For Calibration :::::
Code
Code
Code
Code
Code
HI 4005-00
Ionic Strength Adjuster (500 mL)
HI 4005-01
Hanna 0.1 M CO
2
Standard
(500 mL)
HI 4005-03*
Hanna 1000 ppm CO
2
Standard
(500 mL)
*Please Note: This calibration standard is ppm as CaCO
3
For Maintenance:
For Maintenance:
For Maintenance:
For Maintenance:
For Maintenance:
HI 4005-40
Hanna Carbon Dioxide Fill Solution
(4 X 30 mL)
HI 4005-45
Hanna Carbon Dioxide Conditioning
Solution (500 mL)
HI 4000-47
Bulk package of 10 each
HI 4000-47-4 and HI 4000-47-7
Buffer Packets
HI 4005-53
Replacement Membranes Caps
(3 Membrane Caps)
HI 4000-54
Replacement pH/reference Electrode
Assembly for CO
2
HI 740155P
Capillary Pipettes (20 piece)