Alarm connections, Feed slope cal zero cal – Hanna Instruments HI 9931 User Manual

Page 13

Advertising
background image

13

SET EC

ALARM

LINE

BL DOSING PUMP

0

SECONDS

mS

1.6

0

TIMER

MINUTES

90

45

FINE

COARSE

PROPORTIONAL SETTINGS

ALARM

AUTO

MANUAL

SET

READ

FERT.

SET POINT

HI 9931

1

10

2.5

5

7.5

0.8

mS

EC

FEED

SLOPE

CAL

ZERO

CAL

EC

0

1

2

ALARM

mA OUTPUT

4/20

0/20

mS

gram). The terminals are powered

terminals are powered

terminals are powered

terminals are powered

terminals are powered and hence you do not

do not

do not

do not

do not

need an external power supply

need an external power supply

need an external power supply

need an external power supply

need an external power supply for the pumps or valves.

ALARM CONNECTIONS

• The operator can select an alarm thresh-

old of 0.0 to 2.0 mS/cm for HI 9931
and 0 to 400 ppm for HI 9934 by
turning the alarm knob (see 13 -
Functional Diagram). If the actual mea-
surements are above the setpoint by a
margin greater than the user-select-
able alarm threshold, the alarm terminal is activated.
The alarm can be selected as normally closed ("NC") by connecting
the external device to the C and NC terminals or normally open
("NO") by connecting the external device to the C and NO
terminals.

• When activated, the alarm contacts will open or close, triggering

the mechanism of your choice. When the alarm is activated

alarm is activated

alarm is activated

alarm is activated

alarm is activated

all other terminals

all other terminals

all other terminals

all other terminals

all other terminals (such as dosing relay etc.) are

are

are

are

are

disactivated

disactivated

disactivated

disactivated

disactivated. The alarm LED light also comes on.

• The alarm AUTO/MANUAL switch (see 7 - Functional Diagram) is

only to disable the alarm terminal

disable the alarm terminal

disable the alarm terminal

disable the alarm terminal

disable the alarm terminal (e.g. the

buzzer will not sound). However, all other functions
such as disactivation of the dosing relay remain
unvaried, i.e. the pump ceases to dose until the
alarm condition is alleviated.

EC

0

1

2

ALARM

mA OUTPUT

4/20

0/20

mS

TDS

0

200

400

ALARM

mA OUTPUT

4/20

0/20

ppm

SET EC

ALARM

LINE

0

SECONDS

mS

1.6

0

TIMER

MINUTES

90

45

FINE

COARSE

PROPORTIONAL SETTINGS

ALARM

AUTO

MANUAL

SET

READ

FERT.

SET POINT

HI 9931

1

10

2.5

5

7.5

0.8

mS

EC

FEED

SLOPE

CAL

ZERO

CAL

EC

0

1

2

ALARM

mA OUTPUT

4/20

0/20

mS

EXTERNAL ELECTRICAL

DEVICE ACTIVATED BY

AN ALARM CONDITION

ALARM

AUTO

MANUAL

Advertising
This manual is related to the following products: