Hanna Instruments HI 504901 User Manual

Page 13

Advertising
background image

25

24

CONFIGURATION SETTINGS

The setup procedure is divided into four different sections,
displayed on four different folders inside the main window:

• General Options Setting (see “General Options Setting”)
• RS232 Options Setting (see “RS232 Options Settings”)
• RS485 Options Setting (see “RS485 Options Settings”)
• Digital I/O Options Setting (see “Digital I/O Options Set-

tings”)

Five buttons are available on the bottom of the window, which
can be pressed for performing the following actions:

“Update All” button:

Press this button to send the complete configuration to the
HI504901 device. It is possible to test all RS232 and RS485
devices for connection or not. In this way the HI504901 inter-
face can be configured even if devices will be connected only
on a second time to RS232, RS485 and digital input port.
If the PIN code is changed during configuration, it will be
checked and this operation lasts about 30 seconds. If no
error occurs, the message “HI504901 device correctly up-
dated!” will be displayed. Otherwise the occurred errors list
will be shown and the previous configuration will be kept in
HI504901 memory.

Note

If no error occurs during configuration, the previous
HI504901 setup will be lost. At start-up, 3 attempts for en-
tering the cellular PIN code are available (see “General op-
tions setting” section) and at each update with a wrong PIN
value, an attempt will be lost. The SMS’s stored in the SIM
card will be erased.

Note

If an error occurs on cellular phone before pressing the “Up-
date All” button, the cellular phone will be turned off and on
again for trying solving the error condition. This procedure
lasts about 30 seconds.

“Load” button:

Press this button to load on the PC the last configuration stored
in the HI504901 memory.

Note

By loading the HI504901 configuration, all parameters modi-
fications made till that moment will be lost. At program start-
up, an automatic loading is performed.

Note

At the start-up of HI504901SW program, the application

In the “Advanced Settings” section it is possible to give to the
modem connected to the PC a particular configuration for
the initialization string and the dial string. Note that in the
most common cases the default setting can be used. On
“Serial Communication Port” section select the COM port to
which the modem is connected.
When “OK” is pressed, the software will try to establish a
data call between the PC and the HI504901 device, and
then it is possible to proceed with the configuration (see “Con-
figuration Settings” section).

Note

If no answer is received from HI504901, an alarm window
will be displayed by application software. Check if the mo-
dem line is busy, or HI504901 is busy (a remote configura-
tion or a remote connection or a polling procedure are tak-
ing place), or HI504901 cellular phone is over coverage.
Try later for a new remote configuration attempt.