3. Safety Distances

Within a radius of 60 cm in front of and 55 cm
around the stove, fl ammable, combustible, or
heat-sensitive materials (e.g. furniture, wood or
plastic panelling, curtains, etc.) are not allowed to
be located in the heat radiating area of the fire box
window (fig. 1).

Behind the stove, outside the area of radiation, a
distance of 8 cm must be maintained to any flam-
mable materials (fig. 1).

WARNING!
Flammable flooring materials (e.g., wood,
laminate, carpeting,) must be protected
with a floorplate made of non-combustible
material (e.g., tiles, safety glass, slate, or

sheet steel).

The size of the floorplate must be larger
than the base of the stove by at least 50
cm in front and at least 28 cm at the sides

of the stove (fig. 2).

4. Connection of Multiple Devices in

Direct Vent Operation

When the Asmara is operated as a direct vent mod-
el, more than one device can be connected to the
chimney under the following conditions:

CAUTION!
All connected fireplace stoves must be in
the same building unit or in the same ef-

fective area of the ventilation system.

The inlets for the combustion air ducts
are located in areas of equal pressure
(same pressure ratios), wind-induced
pressure fluctuations have to be avoided.

The inlets for the combustion air ducts

are located in areas of equal pressure
(same pressure ratios), wind-induced
pressure fluctuations have to be avoided.

Dimensions in cm

Dimensions in cm

fig. 2

60

55

55

48

48

28

28

50

fig. 1

floorplate

8

60

55

55