30

IND100129-138

PCA100293-1

Specifications - NMEA / IEC COM Module RS-422 / RS-485

1/2

This information may not, in whole or in part, be copied, photocopied,

reproduced, translated or reduced to any electronic medium or machine-

readable form without the prior written consent of Hatteland Display AS.

The products may not be copied or duplicated in any way.

Dimensions might be shown with or without decimals and indicated as mm [inches]. Tolerance on drawings is +/- 1mm. For accurate measurements, check relevant DWG fi le.

DATA SHEET

Hatteland Display AS, Åmsosen, N-5578 Nedre Vats, Norway

Tel: (+47) 4814 2200 - [email protected] - www.hatteland-display.com

4 channel RS-422 / RS-485, NMEA / IEC COM Module

Manufacturer:

Hatteland Display AS

Product:

4 channel RS-422 / RS-485 COM module

Typenumber:

PCA100293-1

Last Revised:

19 Nov 2014

Revision#:

15

The Hatteland Display COM modules provide the system with quad independent COM channels. The module is attached to the
motherboard via standard USB interface. Application software access the COM channels as standard COM devices, i.e. in the normal
case is there no requirements for additional software development. This module will mainly be integrated, electrical and mechanical,
in the final products, such as; Series X 12, 13, 15, 17, 19, 24, 26 inch Panel Computers and selected Stand-alone Computers.

Description:

Internal USB to 4 channel x RS-485 / RS-422 isolated
• Features

- 4 independent channels (If card is replaced most OS will not change COM port number).

- Outputs are short circuits protected. Inputs are protected.

- Driver strength are approved.

- All channels is fully isolated, channel to channel and channel to chassis.

- Classified towards IEC61162-1 and IEC61162-2.

- Tested according to EN61162.

- NMEA-183 Compliant.

- All requirement for usage in ECDIS applications/systems is fulfilled.

• Absolute Max voltage applied to outputs

-8V to +13V

• Data Rate / Technical Data Output

- Outputs 230kbps (Theoretically 400kbps).

- ±15kV ESD protection on all RS-485 signals.

- Isolation rating = 2000VRMS, not intended for connection to live power nets.

• Transmitter enable mode

- Standard mode is automatic.

- Standard Mode will accept send by RTS, but will in fact ignore RTS.

- Each channel have a overide jumper

*

which can be used to force the transmitter to

always be active. See below and page 2 for details.

• Cable connector

4 x Phoenix 1827732 (MC 1,5/ 5-STF-3,81) Terminal Block (see illustration below)

• Supported Operating Systems (OS)

Embedded Enterprise (WEE): Microsoft® Windows® XP Professional (Eng, SP3, SP2c),

Microsoft® Windows® Server 2003/2008/2008R2 (Eng), Microsoft® Windows®

2003/2008/2008R2 (Eng), Microsoft® Windows® 7 Professional/Ultimate (Eng, SP1).

Linux: openSUSE® 11.4, Fedora™ 15, Ubuntu® 10.04 LTS, Ubuntu® 12.04 LTS.

• Drivers

For updates, please visit:

http://www.ftdichip.com/Drivers/D2XX.htm

Note: Listed Operating Systems above are hardware/platform dependent. Please check datasheet for speci c unit if OS is supported.

• Test and certi cate

Hatteland Display standard,

(tested / type approved by the following classification societies):

IEC 60945 4th (EN 60945:2002), IACS E10, ClassNK - Nippon Kaiji Kyokai,

GL - Germanischer Lloyd, DNV - Det Norske Veritas, ABS - American Bureau of Shipping,

CCS - China Classification Society (Pending), BV - Bureau Veritas,

LRS - Lloyd’s Register of Shipping (Pending), EU RO MR - Mutual Recognition

Note: Product below for illustration only. Location of module and product size/design may differ. Connector/pinning remain the same.

Illustration and Pinning:

4 Ports (Virtual COM) identi ed in the Operating System (OS):
COMx (A), COMx (B), COMx (C), COMx (D)*

*

Configuration dependent, x = next available port number(s) OS.

RS-485 Half Duplex (2-wire, supports ECHO) Con guration:

Connect TX and RX pair-wise: TX- to RX-, TX+ to RX+.

*Note: The jumper for “force of transmitter” is open by factory default. For some custom

models this jumper is preset to closed (active), in that case unit has to be opened and jumper set to open to allow Half Duplex mode.

5-pin Terminal Block 3.81

PIN 01 TxD- Transmit Data Negative

PIN 02 TxD+ Transmit Data Positive

PIN 03 GND Isolated Ground

PIN 04 RxD- Receive Data Negative

PIN 05 RxD+ Receive Data Positive

PIN 06 TxD- Transmit Data Negative

PIN 07 TxD+ Transmit Data Positive

PIN 08 GND Isolated Ground

PIN 09 RxD- Receive Data Negative

PIN 10 RxD+ Receive Data Positive