Periodic Test:

1. Every thirty (30) days the ODORATOR should be operated with the

power switch on and while not hooked up to a gas supply.

2. Wait about 30 seconds and then position the nose about 3/4 inch (20

mm) above the exhaust port and sniff the exhaust.

3. If no odor is detected, turn the ODORATOR “OFF”. The ODORATOR

has not absorbed the odorant and is usable.

4. If an odor is detected, turn the ODORATOR “OFF” and send it to the

nearest Heath Repair Center (Regional Office) listed on page 20. The

odor is an indication that the ODORATOR has absorbed the odorant

and must have its internal tubing replaced and gas flow components

cleaned.

The forms on pages 8-11 are provided to document the Periodic Tests

and are as a courtesy only. Company procedures will define how records

are kept and in what format.

Calibration:

For regulatory compliance, instrument calibration and maintenance a

factory calibration is recommended every 12-15 months from the date

of the previous factory calibration. Only Heath factory or factory trained

personnel should perform ODORATOR calibration. Factory recognized

labels and seals maintain warranty.

Refer to page 20 for Heath repair and calibration centers.