Fault description

4

2. High accuracy, when the battery is fully charged, the voltage of
each cell is: LiPo(4.20±0.01V ).
3. Easy to use and operate.
4. The charging state of each cell is clearly showing.

1.. If the indicator light is red and blinks, please check if the
balance port is connected completely, and check if the functions
of cell which correspond to this indicator is good. (Please Note:
when the indicator blinks red, this state must be reset by cutting
off power, so when the indicator blinks red, firstly please check
whether the corresponding cell is normal and the balance port is
connected well, if both of them have no problem. Then go to cut
off power for a while, and turn on power to recharge.
2. The input voltage is too high (more than 18V), the red lights is
rolling in the middle and send out sharp sound.
3. The input voltage is too low (less than 11 V), the green lights is
rolling in the middle and send out the sharp sound.
4. After a battery connected, if the voltage of which cell is too
high, the corresponding light will blink (between red and green
colors) while other lights are green color, and sent out the sharp
sound.
5. After a battery connected, if the voltage of which cell is too low,
the corresponding indicator will blink (between red and green col-
ors) while other lights are red color, and sent out the sharp sound.
6. Other errors, such as insert the balance port in the wrong
direction, disconnect the main charging mouth during charging
processes suddenly, etc. Then all lights flashing between red and
green colors, and send out the sharp sound.