SERVICE MANUAL

ELECTRICAL SYSTEM

34

909 6577 000(1)2006-02

ELECTRICAL SYSTEM

(WET OR GEL) BATTERY REMOVAL/INSTALLATION AND SETTING [RAZOR SV 17]

Disassembly

1.

Check that the switches (5 and 6) are turned to “0”.

2.

If there is recovery water in the tank (43), drain it through the hose (22).

3.

Disconnect the vacuum hose (29) from the squeegee (17).

4.

Open the cover (12).

5.

Grasp the recovery water tank (A) in the area (B) and lift it, as shown in the figure, then disconnect the vacuum hose (C)
from the tank and remove the tank (A) together with the hoses (D) and (E).

6.

Disconnect the battery terminals (50).

7.

Remove the batteries (50).

Setting (WET or GEL) before installation

8.

If the type of battery chosen to be installed is different from the removed one (not WET but GEL, or viceversa), before
installing and connecting the new batteries, the machine electronic board setting must be performed according to the
following procedure.

9.

Remove the screws (F) and carefully pull out the electrical component box cover (G).

10.

Set the microswitch (H) to WET or GEL position according to the type of battery that is to be installed.

11.

Reinstall the electrical component box cover (G) and tighten the screws (F).

Battery assembly

12.

Once the setting is performed, install the batteries on the machine according to the diagram (51).

13.

Connect the battery terminals (50).

Battery charger

14.

Charge the batteries.

Reset

15.

Carry out steps from 3 to 5 in the reverse order.

S301369

WARNING!
Do not move the adjacent switch (I).