8. Back Panel Interface

PLM+ SERIES Operation Manual rev 1.0.0

63

Table 8.14: RJ45 Wiring & Pin Out Description

Figure 8.15: RJ45 Wiring & Pin Out Diagram

When the device is connected to an active network, the yellow LINK LED illuminates above the connector in use.
Data activity on the network is indicated by illumination of the green ACT LED. It is normal for the ACT LED to
flicker either sporadically or continuously.

8.4.1. Primary Network Connection

4

The Primary Network connection is used for Lake Controller connectivity and Dante digital audio. Please refer to
section 4.2 for additional information.

8.4.2. Secondary Network Connection

5

The Secondary Network connection may be used for a redundant Dante digital audio network. Please refer to
section 4.2 for additional information.