Appendix 32, C 16:4 – Lab.gruppen C Series 88:4 User Manual

Page 39

Advertising
background image

6. Appendix

32

C Series C 88:4, C 68:4, C 48:4, C 28:4 and C 16:4 Operation Manual rev 2.2.3

C 16:4

Level

Load

Rated power

Line Current *2)

Watt *1)

Thermal Dissipation

115 VAC

230 VAC

In

Out

Dissipated

BTU/hr

kCal/hr

Standby with remote power off via NomadLink

0

0

0

0

0

Powered on, idling.

129

0

129

440

111

Amp (I)

Watt

Pink noise (1/8
rated power)

8 Ω / Ch.

400 x 4

8.6

4.3

526

200

326

1112

280

16 Ω / Bridged

800 x 2

4 Ω / Ch.

300 x 4

8.2

4.1

485

150

335

1143

288

8 Ω / Bridged

600 x 2

2 Ω / Ch.

n.r.

*4)

4 Ω / Bridged

n.r.

*4)

100V / Ch.

400 x 4

7.6

3.8

463

200

263

897

226

200V / Bridged

800 x 2

Pink noise
(max power)
*3)

8 Ω / Ch.

400 x 4

16.2

8.1

1046

533

513

1749

441

16 Ω / Bridged

800 x 2

4 Ω / Ch.

300 x 4

15.2

7.6

953

400

553

1887

475

8 Ω / Bridged

600 x 2

2 Ω / Ch.

n.r.

*4)

4 Ω / Bridged

n.r.

*4)

100 V / Ch.

400 x 4

14.4

7.2

944

533

411

1401

353

200 V / Bridged

800 x 2

Mains connector, 230 V CE version

16 A, CEE7

Mains connector, 115 V ETL version

15 A / 5-15P

*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and

specifi ed here is what is known as the “Active Power” in the amplifi er providing useful, real-world values of power consumption and heat dissipation.

*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.

*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation.

Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped

even if operation is momentarily in excess of max. ratings.

*4) Regarding n.r. (not recommended) notes: The amplifi er will be fully operational in bridge-mode into 2 or 4 ohms, but due to physical

constraints in the construction, the max. output power will not be signifi canty higher than running individual channels and therefore this mode of

operation is not recommended.

Table 8.4e: C 16:4 Current Draw and Thermal Dissipation specifications

Advertising
This manual is related to the following products: