Rear panel features, Gain, Sensitivity – Lab.gruppen iP 1150Q User Manual

Page 7: Link switch, Operation modes, Stereo mode, R= ob^o=m^kbi=cb^qrobp, Ip 1150q, Rko= iáåâ=лпбнеь, Rkp= lééê~нбзе=гззйл

Advertising
background image

R= ob^o=m^kbi=cb^qrobp=

Before turning the amplifier on please read the following sections to make sure that the unit is set up
properly for your specific application.

RKNKN= d~áå=
The gain of the iP 1150Q is fixed to 32 dB

RKNKO= pÉåëáíáîáíó=
Sensitivity is defined as how many volts (rms) or dBu (referred to 0.775Vrms) are required to get full
output power. As the output power varies with the load impedance, usually 4 ohms is the reference.


iP 1150Q

LOAD CONFIGURATION

Volt rms

dBu

16 ohms Quad (4 channel)

0,81

0,4

8 ohms Quad (4 channel)

0,81

0,4

4 ohms Quad (4 channel)

0,71

-0,8

2 ohms Quad (4 channel)

0,58

-2,5

16 ohms Stereo (2 channels bridged)

0,98

2,1

8 ohms Stereo (2 channels bridged)

0,71

-0,7

4 ohms Stereo (2 channels bridged)

0,59

-2,4

Sensitivity


RKO= iáåâ=лпбнЕЬ=

The Link switches located on rear panel (switches between the four XLR input connectors) are for
changing the operation mode of the amplifier. (See below, section 5.3).

RKP= léÉê~нбзе=гзЗЙл=

RKPKN= píÉêÉç=гзЗЙ=

In this mode, both channels operate independently of
each other. This is used for all 2 or 4-channel modes,
such as stereo and bi-amping. Set the switches in
depressed -OUT position for the stereo mode. The
level attenuators on the front panel will control the
respective channels levels.
Never connect either output terminal to ground
or in parallel
. The recommended minimum nominal
impedance, for quad or tandem stereo operation, is 2
ohms per channel.

i~ÄKÖêìééÉå== =

=

=

=

=

========================

S

rëÉê=j~ем~д===бm=NNRMn=====sÉêëáçå=MKP=======OMMPJMOJOR=