DIMENSIONS: 20 ½ L x 16 ¾ W x 8 ½ D

WT 67 LBS

*Actual Current and Voltage, charge and discharge, start at zero, but Digital Meters
may not read to zero.

VI.

CHANGING THE AC LINE INPUT FROM 115 TO 230 VOLTS.

WARNING:

Before change-over, the AC line plug must be physically

unplugged from any wall outlet or switch box or serious injury or death may

result from AC line electrical shock.

a.

Unless otherwise specified 4159 is shipped connected

in the 115 Volt AC position and a standard USA 125

Volt 15 ampere 3 wire grounded plug is connected to

the AC line cord.

b.

To change the AC line input from 115 Volt to 230

Volt perform the following:

1.

Remove the large louvered panel on the

power section of the unit. Wired to the large

main transformer is the terminal strip with

two jumpers. The diagram below denotes the

jumper arrangement for AC line input of 115

or 230 Volts. The user will have to adapt or

change the AC plug to conform to the AC

line mains receptacle. For 230 Volt operation

the two jumpers may be placed together on

the 2 and 3 terminals so that the second

jumper is not lost if change over back to 115

Volts is required in the future.