background image

Link Lite Black Max Section 3 - Installation

3-8

Figure 3.7. Shows remote segment units
mounted on a straight side press with
columns extended beyond the bed and
slide.

Figure 3.7:

Remote segment Black Max

units mounted between columns of straight
side power press to detect a person standing
inside the primary sensing field.

The mounting requirements for remote
segment Black Max units are generally the
same as for main transmitter and receiver
units except that when used for
supplemental guarding between the main
sensing field and the hazard, there is no

safety distance, D

s

, requirement for the

location of remote segment units.

NOTE!

If remote segment units are used in

any manner intended to extend and be part
of the main sensing field, safety distance
requirements will then apply to the remote
segment units.

Figure 3.8:

Remote segment Black Max units oriented at an angle to sense a person

between the primary sensing field and the hazard.