Microlink: operator interface terminal – LINK Systems Microlink User Manual

Page 25

Advertising
background image

MicroLink: Operator Interface Terminal

Manual Revision 1.0 4/20/99

B-1

APPENDIX B. ELECTRICAL SPECIFICATIONS

B.1 MicroLink / MultiSet Enclosure

Size:

11.2" wide, 7.2" high, 4" deep

Operating Temperature:

45°C (113°F) Maximum Ambient

B.2 801-1 MicroLink Logic Board

Input Power Supply:

Voltage:

115VAC ± 15VAC, 60 Hz, Single Phase

Fuse:

250 mA, Slow Blow, (5mm x 20mm)

Electromechanical Relay:

Voltage:

120VAC, 60 Hz

(or) 30VDC

Current:

5Amp Continuous (AC or DC)

B.3 801-3 Air System Control Board

Electromechanical Relay:

Voltage:

120VAC, 60 Hz

(or) 30VDC

Current:

5Amp Continuous (AC or DC)
Normally Open, Energized Closed

AC Solid State Relays:

Voltage:

120VAC, 60 Hz

Current:

1Amp Continuous
20 Amp 16ms
5 Amp 75ms

Fuse:

2 Amp Fast-Blow Picofuse

B.4 801-4 Rotary Shut Height Control Board

AC Solid State Relays:

Voltage:

120VAC, 60 Hz

Current:

1Amp Continuous
20 Amp 16ms
5 Amp 75ms

Fuse:

2 Amp Fast-Blow Picofuse

B.5 801-5 Linear Shut Height Control Board

AC Solid State Relays:

Voltage:

120VAC, 60 Hz

Current:

1Amp Continuous
20 Amp 16ms
5 Amp 75ms

Fuse:

2 Amp Fast-Blow Picofuse

Advertising