Lodar 4 Function relay Receiver with master output and Standard Transmitter User Manual

Page 2

Advertising
background image

+ Positive

12/24 Volt supply

- Negative

0 Volts

F1, F2, F3 & F4

Outputs to F1 through F4

M

Master Output

ST

STOP, when grounded shuts down the receiver

Vs- Vs+

12/24 Volt supply for control circuits (Used when link is broken to allow

switching of DC Voltages outside normal operating limits)

ANT

Blade connector for internal antenna

SMA

Aerial connection for external antenna (internal antenna must be removed)

LK1

Master Selection by jumper (AP = Parallel, AM = Continuous)

LK2

RS232 for programming

LK3

RS232 for interface with other RS232 modules

LK4

Connected when using parallel master, connects safety circuit

Make connections into plugs supplied but not shown.

+ RED

- BLACK

F1 GREEN

F2 YELLOW

F3 BROWN

F4 BLUE

M WHITE

LED marked “5V”

Indicates power
supply for control
circuits is OK

LED’s marked

“F1 - F2 - F3 - F4 and M”

When ON indicate an

output to that function

LED marked “FAULT”

Indicates an overload is
present; the System
cannot be RESET until
overload is removed.

This LED blinks for 20
seconds when the
Receiver is initially
powered. A replacement
Transmitter has to be
registered during this 20
second period.

LED marked “SET”

Indicates system

is active

MASTER OUTPUT

Configuration of Master Output
(not 9X00) is by the BLUE jumper.

either PARALLEL
Activated by any Transmitter FUNCTION
but not STOP or RESET
Connect jumper across A-P

or CONTINUOUS
activated by Transmitter RESET
de-activated by Transmitter STOP
Connect jumper across A-M

JUMPER (RED) MUST BE REMOVED WHEN
LK1 IS SET TO CONTINUOUS (A-M)

LK4

VOLTAGE
Working Range
12 Volts to 36 Volts DC
Absolute Limit
8 Volts to 40 Volts DC

Note 42 Volt System
48 Volt Max Limit is
currently Special Order

9004RX.01E