Function settings, Features – LW Measurements PIZA 25 Bench Scale User Manual

Page 4

Advertising
background image

FUNCTION SETTINGS

1. Press and hold [HOLD] key then press [ON/OFF] key to turn on the scale, the

display will show A-ON or A-OFF, press [ZERO] key to select on or off (ON

means auto power off function activate, OFF means auto power off function

inactivate).

2. Press [UNIT] key, the display will show L-ON or L-OFF, press [ZERO] key to

select on or off (ON means auto backlight function activate, OFF means auto

backlight function inactivate).

3. Press [UNIT] key, the display will show P-XX. Press ZERO key to select OFF,

key, con and Stb. (OFF means RS232 function inactivates, KEY means that

output the data by pressing [PRINT] key. Con means that output the data

continually. Stb means that output the data when reading is stable)

4. Press [UNIT] key, the display will show J-ON or J-OFF, press ZERO key to

select ON or OFF. (ON means showing zero when turn on the power, OFF

means showing weight placed when turn on the power.)

5. Press [UNIT] key, the display will show F-Nor, F-PEA or F-Ani. Press ZERO

key to select Nor or PEA or Ani. (Nor means normal weighting function activate.

PEA means peak hold weighting function activate. Ani means animal weighting

function activate).

6. Press [UNIT] key, the display will show N-dsp or N-Ind. Press ZERO key to

select dsp or Ind. (dsp means it can display synchronously as a displayer for

another indicator through the RS232 socket. Ind means it is only a indicator for

the scale)

7. Press [UNIT] key, the display will show Kd 50 or Kd 100 or Kd 200 or Kd400.

(press [ZERO] key to select animal scale anti-shock range among 50, 100, 200,

400)

3

Features

1. Display options:5 digital LCD

2. Power:AC adapter 9V 100mA

3. Auto back light (selectable)

4. Auto off (selectable)

5. Operating Temperature:0-40

℃(32-104℉)

6. Operating Humidity:25%~95%RH

7. 5 Keys:ON/OFF, ZERO, UNIT, HOLD, PRINT, and special foot switch for

TARE function

ZERO

This key is “Zero” feature if load is below 10% of full

capacity or a negative value

UNIT Toggle among different units

ON/OFF Turns the scale power On or Off

HOLD Press this key to store weight value

PRINT Press once and send weight information once.

8. Zero Range (0 to 10% of full capacity)

9. Tare Range (10% to full capacity)

10. Error Message indication:

Err-0 Overload

Err-5 Unstable when power on

Err-c Calibration code is not enough or operation error.

Low battery indication

11. Two calibration weight units (Optional): kg , lb

12. Open calibration capacity

13. Zero range: + 10% of full capacity

14. Three modes : Normal mode / Setting mode /Internal Auto Calibration

mode

15.

RS232 function

8