STANDARD OPERATION FEATURES:

This unit has the Pounds to Kilogram conversion feature. If this feature is

enabled, be sure that all calibration is done in Pounds. A second output has

been added to provide data to a remote computer or display separate from a

printer.



PANEL DESCRIPTIONS



Front panel:

a. 0.54 inch 6 digit LED display

b. 6 LEDs for Motion,Ovld, Gross,Net,Ib,Kg

c. 5 function key

Annunciators:

MOTION: This light is on whenever the scale is motion.

OVLD: This light is on whenever the scale is overload

GROSS: Indicates that the indicator is displaying gross weight.

NET: Indicates that the indicator is displaying net weight.
Ib: Indicates the “lb” unit of the displayed weight.
Kg: Indicates the “kg” unit of the displayed weight.

-1-


KEY FUNCTION:

1. ZERO:

“Zero” feature works if load is between 0 to 100% of full capacity.

To bring the scale to a zero balance reading, press the ZERO button.
The button will not activate if the MOTION lamp is on.

2. * (UNIT):

Push to switch between lb and kg. Each time the button is pushed,

the tare weight will be automatically cleared.

3. GROSS/NET:

Press this key switch between Gross or Net mode. The lamp will

Light to indicate which mode is being displayed.

4. TARE:

“Tare” feature works if load is between 0 to 100% of full capacity.

Multiple tare can be used provided the total mass does not exceed

the weighing capacity of the scale .

When the weight is stable(no motion), press the TARE button, and

hold for one display update. If the gross weight was not a negative

value, the tare weight now equals the gross weight and the display

will show a NET weight of zero.

5. PRINT:

Press this button to activate an optional printer.