Absolute maximum ratings, Recommended operating conditions, Low speed electrical characteristics – Delta Electronics 10GBASE-SR SFP+ Optical Transceiver LCP-10G3A4EDR User Manual

Page 2: Lcp-10g3a4edr

Advertising
background image

LCP-10G3A4EDR

DELTA ELECTRONICS, INC.

2 Revision:

0B

2008/9/5

www.deltaww.com

Absolute Maximum Ratings

Parameter

Symbol

Min.

Typ.

Max.

Unit

Storage Temperature

T

S

-40 85 ºC

Supply Voltage Range @3.3V

V

CC3

-0.5 3.6 V

Recommended Operating Conditions

Parameter

Symbol

Min.

Typ.

Max.

Unit

Case Operating Temperature

T

C

-5 +70 ºC

Supply Voltage @3.3V

V

CC3

3.135

3.30 3.465

V

DC Common Mode Voltage

V

CM

0 3.6 V

Low Speed Electrical Characteristics

(V

CC

=3.135V to 3.465V)

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

Total Supply Current

I

CC

300

mA

Power Consumption

1

W

V

OL

0 0.4

V

TX_Fault, RX_LOS

V

OH

Host_Vcc-0.5

Host_Vcc+0.3

V

V

IL

-0.3

0.8 V

1

TX_Disable

V

IH

2.0 VccT+0.3

V

1

V

IL

-0.3

0.8 V

2

RS0, RS1

V

IH

2.0 VccT+0.3

V

2

1. Shall be pulled up with 4.7k-10k ohms to

VccT in the module.

2. Shall be pulled low to

VeeT with a 30k ohms resistor in the module.

Advertising