Operating heater – Desa VF-18P-PJD User Manual

Page 17

Advertising
background image

www.desatech.com

111826-04A

17

OPERATING HEATER

Continued

Set Timer

• Switch to timer mode by pressing the SET

button briefly.

• Press the SET button until P1 flashes.

• Set the hours with and minutes with .

• Press SET briefly for the next burner cycle

time.

• If all 4 times are set, pressing the OFF button

or waiting will complete the programming.

TO TURN GAS OFF

TO APPLIANCE

Shutting Off Heater

Press OFF button on remote control to switch

off main gas and pilot gas.
Shutting Off Burner Only (pilot stays lit)

Press to decrease the flame height and shut off

main burner.

MANUAL LIGHTING

PROCEDURE

WARNING: Manual lighting

must be performed by a qualified

service person.

The system has a "MANUAL OVERRIDE"

feature that allows you to light with a match.
Lighting with a Match

1. STOP! Read the safety information on

page 14.

2. Make sure equipment shutoff valve is

fully open.

3. Turn motor-knob clockwise to

to

OFF position.

4. Wait (5) minutes to clear any gas and then

smell for gas around heater and near floor. If

you smell gas, STOP! follow "B" on page 14.

If you do not smell gas, go to the next step.

5. Make sure ON/OFF switch is in "–" (ON)

position.

6. MAN-knob (valve) in MAN position, a

metallic core is visible. (see Figure 17).

7. Push and hold down metal core fully by us-

ing a non-sharp object such as a pen. This

lets the pilot gas flow.

8. Light pilot burner with a match, (see

Figure 18).

9. Continue holding down metal core for about

10 seconds. Pilot should stay lit after releas-

ing metal core. If not, repeat step 1 thru 4.

10. Turn MAN-knob to ON position. This lets

main gas flow.

11. Turn Motor-knob to adjust flame. Knob has

a slipping clutch that allows manual flame

height adjustment as well as adjustment to

pilot gas.

Lighting with Piezo Ignitor

1. Disconnect ignitor cable from receiver and

connect to Piezo Ignitor Tab (see Figure 17

and Wiring Diagram on page 24).

2. STOP! Read safety information on page 14,

3. Make sure equipment shutoff valve is fully

open.

4. Turn Motor-knob clockwise

to the

OFF position.

5. Wait (5) minutes to clear any gas and then

smell for gas around heater and near floor. If

you smell gas, STOP! follow "B" on page 14.

6. ON/OFF switch in "—" ON position.

7. MAN-knob on valve is in MAN position (see

Figure 17), When in MAN position you can

see a metallic core.

8. Push and hold down metal core fully with

a pen while the pilot gas flows.

9. Press and release piezo ignitor button until

pilot lights.

Figure 17 - PJD Control Valve

Piezo
Ignitor
Tab

Metalic
Core for
Manual
Ignition

Piezo Ignitor

ON/OFF Switch

Microswitch

MAN-Knob
in Manual
Position

Motor-
Knob
in ON
Position

Figure 18 - Pilot

Advertising