Electrical characteristics curves – Delta Electronics Series S48SP User Manual

Page 5

Advertising
background image

DS_S48SP3R310_05222008


5

ELECTRICAL CHARACTERISTICS CURVES

Figure 8:

Output voltage response to step-change in load

current (75%-50% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF
tantalum capacitor and 1µF ceramic capacitor. Top Trace: Vout
(100mV/div, 50us/div), Bottom Trace: Iout (2A/div). Scope
measurement should be made using a BNC cable (length
shorter than 20 inches). Position the load between 51 mm to 76
mm (2 inches to 3 inches) from the module

Figure

9:

Output voltage response to step-change in load

current (50%-75% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF
tantalum capacitor and 1µF ceramic capacitor. Top Trace: Vout
(100mV/div, 50us/div), Bottom Trace: Iout (2A/div). Scope
measurement should be made using a BNC cable (length
shorter than 20 inches). Position the load between 51 mm to 76
mm (2 inches to 3 inches) from the module



Figure 10:

Test set-up diagram showing measurement points

for Input Terminal Ripple Current and Input Reflected Ripple
Current.
Note: Measured input reflected-ripple current with a simulated
source Inductance (L

TEST

) of 12 μH. Capacitor Cs offset

possible battery impedance. Measure current as shown below

Figure

11:

Input Terminal Ripple Current, i

c

, at full rated output

current and nominal input voltage with 12µH source impedance
and 33µF electrolytic capacitor (50 mA/div, 1us/div)

0

0

0

0

0

Advertising