REFCO REF-METER-OCTA User Manual
Page 11

English
REF-METER-OCTA User’s Guide
9
5. Press
. The display will automatically change to zero and the RUN indicator will
show to indicate that the program is running.
6. When the applied (or removed) weight exceeds the programmed amount, the alarm will
sound and the DONE indicator will flash on the display.
7. Press any key to stop the alarm.
8. To cancel the RUN mode at any time, press the
key.
NOTE: The RUN mode can only be initiated from the SET mode. If you cancel the RUN
mode by pressing
, and wish to RUN again, press
(the previous set point will be
restored) followed by
again. The display will be zeroed when the program restarts. You
may program the SET mode without starting the RUN mode by pressing
after setting
the program set point. The new value will be saved until next time the SET mode is
activated.
can be used during the RUN mode similarly as described in the HOLD MODE
Tank Capacity Mode
It is often convenient to know the relative amount of material (i.e. refrigerant) remaining in a
container (tank). The REF-METER-OCTA’s Tank Capacity Mode allows a continuous
display of the percentage of material remaining in a tank. In order to compute the
percentage accurately, the REF-METER-OCTA must be trained to know the weights of an
empty and full tank. To train the REF-METER-OCTA Tank Capacity Mode, perform the
following steps:
mode. Refer to the REF-METER-OCTA-PLUS User’s Guide for details.
section. The REF-METER-OCTA-PLUS provides additional functionality when using the RUN