SPECIFICATIONS

80,000 Btu

200,000 Btu

Type of Gas

Propane/LP Only

Propane/LP Only

Gas Supply Pressure to regulator

Maximum

Bottle Pressure

Bottle Pressure

Minimum

5 psig (34.5 kPa)

15 psig (103 kPa)

Gas Supply Pressure regulator out

11" W.C. (2.74 kPa)

10 psig (68.9 kPa)

Ignition

Piezo Ignitor

Piezo Ignitor

Minimum Ambient Temp. Rating

0°F (-17.8°C)

0°F (-17.8°C)

Rating

30,000 - 80,000 Btu/hr 75,000 - 200,000 Btu/hr

(8.79 - 23.4 kW)

(22.0 - 58.6 kW)

Fuel Consumption

1.4 to 3.7 lb/hr

3.5 - 0.3 lb/hr

(.74 – 1.80 kg/hr)

(1.44 - 4.32 kg/hr)

Fuel Orifice Port No.

6

6

Fuel Orifice Port Size

0.0472"

0.0320"

(1.20mm)

(.813mm)

TROUBLESHOOTING

WARNING: Never service heater while it is plugged in, connected

to propane supply, operating, or hot. Severe burns and electrical

shock can occur.

REMEDY

1. Open propane supply valve

slowly

2. Close propane supply valve on

propane tank and reopen slowly

3. Replace burner orifice

4. Check to assure ignitor elec-

trode gap is .195" Check wire

lead for damage. Replace

piezo ignitor and/or ignitor

electrode as necessary

5. Clean or replace pilot assembly

1. Relight, hold automatic control

valve button in 45 seconds

2. Check propane tank(s) for

proper gas supply

3. Tighten connection or replace

thermocouple

4. Replace automatic control

valve

1. Turn valve counter clockwise

to HIGH

2. Replace gas orifice

3. Check gas supply; check

regulator output

4. Consult propane gas supplier

OBSERVED FAULT

Burner fails to light

Pilot lights but goes out when

automatic control valve button

is released

Burn rate is low

POSSIBLE CAUSE

1. Propane supply valve closed

on propane tank(s)

2. Excess flow check valve

closed

3. Blockage in burner orifice

4. Piezo ignition system not

sparking

5. Pilot orifice clogged

1. Not enough warm up time

2. Low gas pressure

3. Thermocouple loose or needs

to be replaced

4. Automatic control valve needs

to be replaced

1. Control valve is on LOW

2. Plugged gas orifice

3. Low gas pressure

4. Low fuel supply