17

As the input signal drops further below the threshold point, downward

expansion increases. A drop in the input level by 20dB would cause the output

level to drop approximately 40dB (i.e., 20dB of gain reduction). In the absence

of any input signal, the expander will reduce the gain so that the noise floor

becomes inaudible.

This means that if a signal is present at the input which consists of primar-

ily bass components, the dynamic filter will reduce mid or high band noise. If no

mid or high band information is present, the filter will close down to a pre-set

cut-off point of 1kHz (allowing only frequencies of 1kHz and below to pass).

However, if the input signal has high frequency components present, the dynamic

filter will open fully to pass the signal and eliminate the possibility of a loss of

high end frequency response.

Downward Expansion

The second half of the HUSH process incorporates downward expansion.

The low level expander of the HUSH system operates like an electronic volume

control. The HUSH system utilizes a voltage-controlled amplifier (VCA) circuit

which can control the gain between the input and the output from unity to 30, 40

or even 50dB of gain reduction. When the input signal is above the user pre-

set threshold point, the VCA circuit remains at unity gain. (This means that the

output signal level is equal to the input signal level.) As the input signal level

drops below the user preset threshold point, downward expansion begins. It is at

this point that the expander acts like an electronic volume control and gradually

begins to decrease the output signal level relative to the input signal level.

Advertising