51

Reloading the user memory from a sequencer

Connect the MIDI OUT of the sequencer to the MIDI IN on the Intellifex XL with a
standard MIDI cable.

Step 1

Turn the FUNCTION SELECT control on the Intellifex XL fully clockwise to the "MIDI
DUMP/LOAD" position.

Step 2

MIDI DUMP LOAD

Turn the PARAMETER SELECT control to the "LOAD USER DATA" position. The
Intellifex XL is now ready to receive the user data from the sequencer.

Step 3

LOAD USER DATA

Play back the user data previously recorded on the sequencer. The Intellifex XL will display
the data strings as it is storing them. The data string and "LOADED" will appear on the
display. After all the user data has been loaded the Intellifex XL will display "USER DATA
LOADED". The entire procedure will take approximately 3 minutes to complete.

Step 4

USER DATA LOADED

Do not play back data from the sequencer faster than it was recorded, as errors may
occur. Errors may also occur if any knob is turned or any button is pressed before the
message “USER DATA LOADED”appears.