页 11, Setting – SkyRC T6200 Charger User Manual
Page 11
T6200
T6200
19
18
PRESET
P1
P2
LiPo
6S 2.0A/1.0A
P3 LiFe 3S 2.0A/1.0A
P4 NiMH 7S 2.0A/1.0A
P5 Pb
6S 2.0A/1.0A
EDIT
EDIT
EDIT
EDIT
EDIT
HOME
LiIon 6S 2.0A/1.0A
PRESET
P1
P2
LiPo
6S 2.0A/1.0A
P3 LiFe 3S 2.0A/1.0A
P4 NiMH 7S 2.0A/1.0A
P5 Pb
6S 2.0A/1.0A
EDIT
EDIT
EDIT
EDIT
EDIT
HOME
LiIon 6S 2.0A/1.0A
CELLS
CAPACITY
BATT TYPE
Pb
Lilon
OPERATION
VOLT
METER
CHARGE
START
SETTING
LiPo
6S
C6.0A / D2.0A
PRESET
LiPo
mAh
P1
BAL CHARGE
The charger can store up to 5 different charge/discharge profiles for your convenience, and the
stored profiles can be recalled quickly without having to go through the setup process.
1. EDIT AND BACK
Touch “EDIT” to set the profiles and “HOME”
to
homepage.
Touch “CONFIRM” to confirm the setting and go back to previous screen.
EDIT
BATT TYPE CELL
Pb
OPERATION CHG CURRENT
CHARGE
DCHG CURRENT
CONFIRM
2S
0.1A
0 1A
.
Please touch “>” to change the battery
type and operation program.
Please touch “-” and “+” to get the right
battery cells count and desired charge/
discharge current.
NOTE:
2. CALL OUT
The basic settings of the profiles are displayed and you could touch the settings bar to enter
to the homepage. All the current settings will displayed in the top of the screen. please
touch and hold the desired operation program to start the progress.
MEMORY PRESET-DATA STORE/LOAD
MEMORY PRESET-DATA STORE/LOAD
You could do SYSTEM SETTING, SAFETY PROTECTION and CHARGER PARAMETER
settings when you enter to Setting program.
Please touch “ ” and “ ” to go to previous or next setting phase and touch “NEXT” to enter
to current setting program.
ITEM
KEY BEEP
BUZZER
LCD LIGHT
THEME
SELECTION
ON/OFF
ON/OFF
1-5
BLUE, RED,
YELLOW, GREEN
DESCRIPTION
The beep sounds at every time touching the screen to confirm
your action. The beep or melody sounded at various times
during operation to alert different mode changes.
The brightness of the LCD can be adjusted basing on
personal preference.
Different color theme can be selected basing on personal
preference.
1. SYSTEM SETTING
▲
▲
ENTER
HOME
LCD LIGHT
5
SYSTEM
SETTING
KEY BEEP
ON
ON
BUZZER
THEME
语 言
中 文
RESTORE
ENTER
NEXT
SETTING
SYSTEM
SETTING
Please touch the referred setting(selections) to change it.
When touching “RESTORE” the charger will restore factory default settings.
2. SAFETY PROTECTION
ITEM
SELECTION
DESCRIPTION
CAPACITY
CUT OFF
SAFETY
TIME
TEMP
CUT OFF
This program sets the maximum charge capacity that will be
supplied to the battery during charge. If the delta peak voltage
is not detected nor the safety timer expired by any reason, this
feature will automatically stop the process at the selected
capacity value.
When you start a charge process, the integral safety timer
automatically starts running at the same time. This is
programmed to prevent overcharge the battery if it proves to
be faulty, or if the termination circuit cannot detect the battery
full. The value for the safety timer should be generous enough
to allow a full charge of the battery.
The battery's internal chemical reaction will cause the
temperature of the battery to rise. If the temperature limit is
reached, the process will be terminated.
OFF
100-20000 mAh
OFF
1-720 Min
20 C/68 F -
80 C/176 F
SETTING
ABOUT
ABOUT
System information: model no., serial no., hardware version,
software version.
SETTING
Lilon
6S C2.0A/D1.0A
BATT TYPE
Pb
LiPo
Lilon
OPERATION
CHARGE
BAL CHARGE
VOLT METER
P2
CELLS
CAPACITY
START
SETTING PRESET
mAh