Third party control protocol – Sonodyne AM41P User Manual

Page 17

Advertising
background image

Description

Command

Response

Parameter Description Valid Range Value Detail

Set Output Level

%PLVL:xyy<CR>

%PLVL=xyy<CR>

x

Output Channel 1, 2, 3 or 4

1 or 2 for 2 channel
amplifiers

yy

Output Level

00 to E1 hex

0.5dB steps where for
example:
01 = -100dB
C9 = 0dB
E1 = +12dB

Set Output Mute

%PMUT:xyy<CR>

%PMUT=xyy<CR>

x

Output Channel 1, 2, 3 or 4

1 or 2 for 2 channel
amplifiers

yy

Mute on/off

00 or 01

00 = Mute OFF
01 = Mute ON

Get Standby Mode

%PGRN:??<CR>

%PGRN=xx<CR>

xx

Mode

00 or 01

00 = Normal
01 = Standby mode

Set Standby Mode

%PGRN:xx<CR>

%PGRN=yy<CR>

xx

Mode

00 or 01

00 = Normal
01 = Standby mode

yy

Mode

00 or 01

00 = Normal
01 = Standby mode

Get Version Info

%PVER:??<CR>

%PVER=AMDxy00P,aabbcccc

xy

Amplifier model 21, 22, 41 or 42 2100P, 2200P,

4100P, 4200P

aa

FW Version
major

bb

FW Version
minor

cccc

FW Revision

Get Amp Status

%PAMP:x??<CR>

%PAMP=xyy<CR>

x

Output Channel 1, 2, 3 or 4

1 or 2 for 2 channel
amplifiers

yy

Status byte

00, 01 or 02

00 = Ok
01 = Thermal
Shutdown 2 = Fault
Shutdown

PAGE 17

AMD SERIES INSTALLATION AND OPERATION MANUAL

THIRD PARTY CONTROL PROTOCOL

Advertising