Switch ratings, Preventive maintenance – SOR Vertical Displacer Top Mounted Series Level Switch User Manual

Page 12

Advertising
background image

12/16

Form 425 (08.12) ©2012 SOR Inc.

Switch Type

Resistive Amperage

Inductive Amperage

110-130 V

A

C

210-250 V

A

C

20-30 VDC

110-130 VDC

210-250 VDC

110-130 V

A

C

210-250 V

A

C

20-30 VDC

110-130 VDC

210-250 VDC

Standard Dry Contact

15

15

5

.5

.25

15

15

5

.4

.13

Hi-Temperature Dry Contact

5

5

1.5

.5

-

5

5

1

.25

-

Gold Contact

1

-

1

-

-

1

-

.5

-

-

Anti-Vibration

15

15

5

.5

.25

15

15

5

.4

.13

High-Amp DC

-

-

10

10

3

-

-

10

10

3

Hermetically Sealed

11

11

5

.5

.25

11

11

.25

.25

.13

Gold Contact Hermetically Sealed

1

-

1

-

-

1

-

.5

-

-

Hi-Temperature Hermetically Sealed

5

5

1.5

.3

-

5

5

1

.25

-

Mini
Hermetically Sealed

DPDT

5

5

5

.5

-

5

5

2.5

.25

-

SPDT

11

11

5

.5

.25

11

11

2.5

.25

.13

Anti-Vibration Gold Contact

1

-

1

-

-

1

-

.5

-

-

Gold Contact Mini-Hermet

1

-

1

-

-

1

-

.5

-

-

Anti-Vibration Mini-Hermet

DPDT

5

5

5

.5

-

5

5

2.5

2.5

-

SPDT

11

11

5

.25

.25

11

11

2.5

.5

.13

Hi-Temperature Mini-Hermet

5

5

1.5

.5

-

5

5

1

.25

-

Extra Hi-Temperature (Ceramic)

1

1

1

.4

-

1

1

.4

-

-

Standard Pneumatic 316SS Fittings

Non-bleed 3-way aluminum valve body. Buna-N O-Rings

150 psig maximum supply, 24 CFM @ 100 psig

Switch Ratings

NOTE: Pneumatic switches must be used with clean, dry air or gas. All switches include a
pre-wired terminal block. These switches have higher current ratings for SPDT than DPDT.

Periodic inspections are necessary to keep the switch in good working order. SOR recommends
a systematic program of preventive maintenance be implemented at the time of installation. The
following precautions are important and will help keep your switch in top operating condition.

Keep the switching mechanism clean. Never leave the cover off longer than absolutely

necessary. There is no need to lubricate any part of the switch.

Inspect switches and wiring monthly. Dry contact switches should be inspected for

excessive wear and misalignment. Pneumatic switch connections and tubing should be
inspected for cracks and air leakage. Repair or replace as required.

Do not operate switches that are defective or malfunctioning. When replacing parts,

refer to Replacement Instructions supplied with the parts and follow instruction
carefully. When in doubt, contact the factory or the SOR representative in your area.

Preventive Maintenance

Advertising