4/4

Form 439 (04.13) ©SOR Inc.

Replacement Parts

14685 West 105th Street, Lenexa, KS 66215

 913-888-2630  800-676-6794 USA  Fax 913-888-0767

Registered Quality System to ISO 9001

sorinc.com

Part Number

Description

3130-052

316SS Float & Actuator Arm Assembly

3130-114

Pneumatic Relay Assembly

Troubleshooting

Symptom

Probable Cause

Float in actuated position
but no output signal.

a. Pilot nozzle-seat worn or damaged. (No seating of
flapper.) Return to the factory or replace the switch.
b. Actuating lever bound up or dirty. Clean or return to the factory.
c. Damaged relay diaphragm. Replace the relay assembly.
d. Relay orifice plugged. Clean.
e. Insufficient supply pressure adjust to 20-60 psi.
f. Output line clogged. Clean.

Float in de-actuated position
but still receiving an output
signal.

a. Pilot nozzle plugged. Clean the pilot nozzle.
b. Actuating lever bound up or dirty. (Flapper remains seated.)
Clean or return to factory.
c. Vent screen clogged. Clean.

Control will not function
when installed but operates
when removed from vessel.

a. Inadequate float travel. Float travel restricted by the
process connection.

Liquid in vessel at the
actuation level but unit does
not respond.

a. Leaky or collapsed float. Replace.
b. Liquid specific gravity too low.
c. Float stem bound up or dirty. Clean.
d. Float travel is obstructed. Verify float can move freely and is
not obstructed when installed.

Slow response.

a. Excessive volume in the output leg.
b. Leaky output line.

Fluttering output.

a. Inadequate volume in the output leg.