Form 916 (03.14) ©SOR Inc.
5/8
ATEX Information
For ATEX Certifi ed Models
Product Type Identification
ATEX Listing Information
Manufacturer’s
Registered Trademark
Location of Product Model
Identification
Drawing 0720558
The certification of this equipment relies upon the following material used in its
construction:
ENCLOSURE MATERIAL:
ALUMINUM 356.0-T6 (COVER AND HOUSING, ASTM B 108)
O-RING COMPOUND: SILICONE, PARKED COMPOUND S1224
The equipment may be used with flammable gases and vapours with apparatus groups
IIC or IIB + Hydrogen (see product nameplate) and with temperature class T5 in the
ambient temperature range -40ºC to +80ºC.
The equipment is only certified for use in ambient temperatures in the range -40ºC to
+80ºC and should not be used outside this range.