Testing, Complete the installation – Desa DUALBRITE 4291 User Manual

Page 4

Advertising
background image

4

598-1234-01

TESTING

Turn on the circuit breaker and light

switch.

The detector is less sensitive to motion di-
rectly towards it and more sensitive to across
motion.

Sensor

Motion

Least Sensitive

Most Sensitive

NOTE: Sensor has a 1

1

/

2

minute warm up pe-

riod before it will detect motion. When
first turned on, wait 1

1

/

2

minutes.

TEST 1 5 10 MIN

ON-TIME

OFF 3 6 DUSK TO

HOUR DAWN

Avoid aiming the control at:

• Objects that change temperature rapidly,

such as heating vents and air condition-
ers.
These heat sources could cause false
triggering.

• Areas where pets or traffic may trigger

the control.

Nearby large, light-colored objects

reflecting light may trigger the shut-off
feature. Do not point other lights at the
sensor.

30 ft.

(9.1 m)

Maximum Range

Maximum

Coverage Angle

6 ft.

(1.8 m)

150°

COMPLETE THE

INSTALLATION

Stuff the wires into the junction box. Make

sure none of the wires get pinched.

Slide the fixture onto the mounting

screws and tighten nuts.

Install one 100 W max. light bulb.

Install the fixture top. Secure with
decorative screws.

After completing the tests on page 5, caulk

fixture mounting surface with silicone
weather sealant.

Junction Box

Switch the on-time to TEST position and

D

UAL

B

RITE

®

switch to the OFF position.

Motion

Advertising