TESTING

❒

Turn on the circuit breaker and light

switch.

The detector is less sensitive to motion di-
rectly towards it and more sensitive to across
motion.

Sensor

Motion

Least Sensitive

Most Sensitive

NOTE: Sensor has a 1

1

/

2

minute warm up pe-

riod before it will detect motion. When
first turned on, wait 1

1

/

2

minutes.

TEST 1 5 10 MIN

ON-TIME

OFF 3 6 DUSK TO

HOUR DAWN

Avoid aiming the control at:

• Objects that change temperature rapidly,

such as heating vents and air condition-
ers.
These heat sources could cause false
triggering.

• Areas where pets or traffic may trigger

the control.

• Nearby large, light-colored objects

reflecting light may trigger the shut-off
feature. Do not point other lights at the
sensor.

30 ft.

(9.1 m)

Maximum Range

Maximum

Coverage Angle

6 ft.

(1.8 m)

150°

COMPLETE THE

INSTALLATION

❒

Stuff the wires into the junction box. Make

sure none of the wires get pinched.

Slide the fixture onto the mounting

screws and tighten nuts.

❒

Install one 100 W max. light bulb.

❒

Install the fixture top. Secure with
decorative screws.

❒

After completing the tests on page 5, caulk

fixture mounting surface with silicone
weather sealant.

Junction Box

❒