OPERATING INSTRUCTIONS

Battery Installation

Automatic OFF

The gage will turn off (the display will go blank) after

30 minutes of no slide movement or pushing of a but-

ton. A push of the ON/OFF button or movement of the

slide will reactivate the display with no loss of position

reading.

ON/ OFF Button

A push of this button will turn the display either on or off with no loss of position reading.

+/- Button

When the gage is activated upon battery installation, the display will read “+” (positive) when the

slide is moving upward and will read “-” (minus) when moving down. A push of this button will

reverse the signs.

HOLD Button

When this button is pushed, the measurement of the display is frozen regardless of movement of

the gage slide and without loss of the zero reference position. A second push will cancel the hold

condition and return the display to the new position of the slide.

In/mm Button

The gage can be changed from inch mode to millimeter mode, or the reverse, with one push of

this button.

3.

1.

Remove and retain the battery slide

locking screws (detail #1).

2.

Move the battery slide up and away from

the gage (detail #2).

3.

Remove the old batteries (detail #3).

4.

Place two fresh CR2450 batteries (No.

PT61120) into the battery slide with the

positive (+) sides facing down (detail #4).

5.

Replace the battery slide by matching up

the grooved slots and then pressing it in

and down.

6.

Re-install the slide locking screw to keep

the battery slide fixed in place.

Insert batteries under two tabs at

an angle as shown, then press

down to lock under the third tab

Detail No. 4

To remove batteries, place screwdriver

under battery as shown and pry up

Detail No. 3

Positive side of battery

Detail No. 1, 2

1.

1.

2.