DS500 Status Signal Access Jumper

The DS500 provides chassis status signals for use by a RAID or system controller.

These status signals identify:

•Chassis Over Temperature Condition

•Fan Failure(s)

•Power Supply Failure(s)

•Chassis Failure (Combination of Over Temp and/or Failures)

Status signals are accessed on Jumper P4 located on the DS500 Power Distribution Board

inside of the DS500 chassis (Figure 14). Signal/pin assignments on P4 are also identified.

Figure 14: Power Distribution Board

NOTE:

Status signals are all ACTIVE LOW and require the use of a pull-up resistor. To ac-

cess each signal, connect the RAID controller ground to the ground pin on P4, and

make the corresponding status signal connection via a pull-up resistor.