Quick Start Guide

III.

Line Interface

1.

Command Line Interface (CLI): Many configuration

parameters may be set using the Command Line Interface
(CLI). The CLI is accessed through the network using a

telnet client, or through the serial port.

a. Open a telnet client and point it to the current IP

Address of the Axess Elite.

(Factory Default is DHCP Assigned, telnet Port 23)

b. Connect to the Serial port. (Factory Default is 9600,8,n,1)

c. Upon connection, press Enter, and then enter the

username and password when prompted.

The example shows the basic commands to set the network

parameters. After setting these parameters, the Axess Elite

will need to be rebooted for the settings to take effect. Any

command that requires rebooting of the Axess Elite will
provide a prompt to do so. All commands may be entered as

required before rebooting. Once the IP address is set, the

following command can be used to prevent DHCP from

altering it: set ipmode static

2. Web Page Setup – Manual: From the Device View

page, click Setup, and then Network. Enter the new IP

Address, Subnet Mask, and Gateway, and then click

Save. Click the Reboot button to restart with the new

settings.

3. Web Page Setup – DHCP: From the Device View page, click

Setup, and then Network. Change the IP mode from Static to
DHCP. Click Save, and then Reboot. The Axess Elite will
automatically obtain
its network settings from the DHCP server. Check the server
IP/MAC
table or use the serial CLI to obtain the new settings.