Test Products International 133 User Manual

Page 17

Advertising
background image

17

16

Application Notes

When measuring resistance of a motor,
make sure the power is disconnected prior
to testing.

Set up the meter following steps under
“Measurement Procedure” on page 17, and
then proceed with the following:

Connect the red test lead to one power

input line of the motor and the black
test lead to the other power input line
of the motor. In most applications if
the reading is OFL, the motor winding
is open.

Connect the red test lead to the frame

of the motor and the black test lead to
the winding. In most applications if a
reading of 0 Ohms is displayed, the
winding is shorted to the motor frame
(ground).

e.

Measuring Resistance

WARNING!

Do not attempt to make resistance measurements with
circuit energized. For best results, remove the resistor
completely from the circuit before attempting to
measure it.

NOTE:
To make accurate low ohm measurements, short the ends of
test leads together and record resistance reading. Deduct
this value from actual readings.

Instrument set-up:

FUNCTION

BLACK

RED

MINIMUM

MAXIMUM

TEST LEAD

TEST LEAD

READING

READING

OHM

COM

V

0.1

19.99M

Measurement Procedure:

1.

Disconnect power to circuit to be measured.

2.

Plug black test lead into the COM input jack.

3.

Plug red test lead into the V

input jack.

4.

Set the rotary switch on the 133 to the desired range
in the OHM function depending on the voltage to be
measured.

5.

Connect test leads to circuit to be measured.

6.

Read the resistance value on the 133.

!

Advertising