TFC Group Grasslin QEG-1S User Manual

Day/ prog run time, Ext hour +1 +2 +3, On1 select

Advertising
background image

EN

Override

Extra Hour

Mode

DAY/

PROG RUN

TIME

OK

Holidays

OFF

am

Thu

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

07 / 02 / 2013

ON1

Select

Operating Manual

QEG-1
QEG-1S

Installation und Montage

Operation and confi guration

Safety Instructions

Quick-start guide – 3 clicks to total control

• To avoid injuries, the device must be installed by a skilled

electrician only!

• Before changing the battery, the device must be disconnected

from the power supply!

• Please observe the national regulations and safety instructions.

• Interferences and changes to the device will invalidate the

warranty and guarantee rights.

• Maximum diameter of the conductors lines for the

terminals: 2 x 2,5 mm

2

Read and observe these instructions to guarantee a perfect function

of the device and a safe operation.

1. connect mains power.

2. Press

OK three times.

Z

Z

The default Standard in-built programme runs.

Z

Z

You can control the QEG with the Override, Extra hour or Mode

buttons.

Please read the full instructions if you want to know more.

Information about the device

What is a programmer?

...an Explanation for householders (as recommended by the Energy

Savings Trust)

Programmers allow you to set ‘ON’ and ‘OFF’ time periods. Some

models switch the central heating and domestic hot water on and

off at the same time, while others allow the domestic hot water and

heating to come on and go off at different times.

Set the ‘ON’ and ‘OFF’ time periods to suit your own lifestyle. On

some programmers you must also set whether you want the heating

and hot water to run continuously, run under the chosen ‘ON’ and

‘OFF’ heating periods, or be permanently off.

Danger! Risk of electric shock!

Z

Z

Installation must be carried out by a
professional electrician!

WARNING

Open/Close housing, Wall mounting

Wiring diagram

General information

Installation and mounting

Danger! Risk of electric shock!

Z

Z

Installation must be carried out by a
professional electrician!

WARNING

N L 1 2 3 4

N

Mains

input

OFF ON

output

L

times

witch /

programmer

wallpla

te

The time on the programmer must be correct. Some types have to be

adjusted in spring and autumn at the changes between Greenwich

Mean Time and British Summer Time.

You may be able to temporarily adjust the heating programme, for

example, ‘Override’, ‘advance’, or ‘Boost’. These are explained in the

manufacturer’s instructions.

The heating will not work if the room thermostat has switched the

heating off. and, if you have a hot-water cylinder, the water heating

will not work if the cylinder thermostat detects that the hot water has

reached the correct temperature.

Description of the device

Your single channel timeswitch provides timing control for your central

heating, letting you set ON and OFF periods to suit your own lifestyle.

• Backlit lcD Display

• Real Time clock

• Up to 3 ON/OFF per day

• automatic summertime / wintertime changeover

• Daily, weekly

1)

and week-weekend

1)

programming possibility

• Different running modes: OFF, aUTO, ONcE, cONTINUOUS and

hOlIDaYS

1)

• Manual override function

• Manual extra hour function

• 3 different pre-programmed profi les, customizable by user

• Boiler service interval indication & actions

1)

Designated use

• The programmer is used to control central heating zone systems or

combi boilers

• Suitable for use in dry rooms only!

• Do not install in the vicinity of devices which generate inductive

discharges (motors, transformers, etc.)

Technical data

Dimensions h x W x D (mm)

95 x 148 x 36

Weight g (approx.)

285

Power supply

230 V AC / 50-60 Hz

Power consumption

< 3 W

Power reserve

> 2h

Switching capacity

3 a 250 V ~ resistive, cos

φ = 1

3 a 250 V ~ inductive, cos

φ = 0.6

Time display

24 h or 12 h aM/PM format

Time setting resolution

– Time of day

– Programmes / min. switching

1 min.

1 min.

Programmes

Selectable (daily , weekly, or

week-weekend)

Number of switchings per day

3 ON/OFF pairs

(2 ON/OFF pairs selectable)

Operating temperature range

0°c ... + 45°c

ambient temperature

-20°c ... + 55°c

humidity range

10 to 90% Rh, non condensing

accuracy

Type ± 1 sec./day at +20°c

Terminal capacity

2 x 2,5 mm

2

Protection type

IP 30

European standards

EN60730-2-7

compliant with building regulations

(Part l Uk) (Part J Scotland)

Running a built-in programme (default programmes)

With the date and time correct, your timer will now be operating to the

built-in programmes. These have been designed to provide heating at

typical times throughout the day.

The built-in programmes give you a starting point that you can

personalise to your own requirements, please see the section “Review/

Edit central heating program” or “Review/Edit domestic hot water

program”.

Built-in programme

STD (DEFaUlT)

Daily

ON1: 06:30 am

ON2: 12:00 pm*

ON3: 04:30 pm

OFF1: 08:30 am

OFF2: 12:00 pm*

OFF3: 10:30 pm

Weekly

1)

ON1: 06:30 am

ON2: 12:00 pm

ON3: 04:30 pm

OFF1: 08:30 am

OFF2: 01:00 pm

OFF3: 10:30 pm

Week-

ON1: 06:30 am

ON2: 12:00 pm

ON3: 04:30 pm Mo - Fr

Weekend

1)

OFF1: 08:30 am

OFF2: 01:00 pm

OFF3: 10:30 pm

ON1: 06:30 am

ON2: 12:00 pm

ON3: 04:00 pm Sa - Su

OFF1: 09:30 am

OFF2: 01:00 pm

OFF3: 10:30 pm

Built-in programme

HOME

Daily

ON1: 06:30 am

ON2: 12:00 pm*

ON3: 04:00 pm

OFF1: 09:30 am

OFF2: 12:00 pm*

OFF3: 11:00 pm

Weekly

1)

ON1: 06:30 am

ON2: 12:00 pm

ON3: 04:00 pm

OFF1: 09:30 am

OFF2: 01:00 pm

OFF3: 11:00 pm

Week-

ON1: 06:30 am

ON2: 12:00 pm

ON3: 04:30 pm Mo - Fr

Weekend

1)

OFF1: 09:30 am

OFF2: 01:00 pm

OFF3: 11:00 pm

ON1: 06:30 am

ON2: 12:00 pm

ON3: 04:00 pm Sa - Su

OFF1: 09:30 am

OFF2: 01:00 pm

OFF3: 11:00 pm

Built-in programme

ECO

Daily

ON1: 06:30 am

ON2: 12:00 pm*

ON3: 05:30 pm

OFF1: 07:30 am

OFF2: 12:00 pm*

OFF3: 10:00 pm

Weekly

1)

ON1: 08:30 am

ON2: 12:00 pm

ON3: 05:30 pm

OFF1: 09:30 am

OFF2: 01:00 pm

OFF3: 10:00 pm

Week-

ON1: 06:30 am

ON2: 12:00 pm

ON3: 05:30 pm Mo - Fr

Weekend

1)

OFF1: 07:30 am

OFF2: 12:00 pm

OFF3: 10:00 pm

ON1: 08:30 am

ON2: 12:00 pm

ON3: 05:30 pm Sa - Su

OFF1: 09:30 am

OFF2: 01:00 pm

OFF3: 10:30 pm

* On/off prgrammes with the same time cancel out - no switching will occur.

The built-in programmes can be selected in the

INSTALLERS MENU.

To access to installers menu, the device must be working in

RUN mode.

INST MENU

DIGI CLOCK

BACKLIGHT

S W CHANGE

PROG TYPE

10 sec.

Review/Edit central heating (CH) program

Depending on the product you can choose between three different

settings: Daily, Weekly

1)

or Week-Weekend (5-2 days)

1)

.

Daily

all days (Monday - Sunday) are programmed

with the same ON/OFF time schedule

Weekly

1)

You can program each day (Monday, Tuesday, ...)

with a different ON/OFF time schedule

Week-Weekend

1)

You can program Monday - Friday with a ON/

OFF time schedule and Saturday - Sunday with

a different one.

You can choose the desired setting in the

INSTALLERS MENU.

Every programme has three pairs of ON/OFF switching times

per day. Each time can be set between 3.00 am and 2.50 am

(on the next day).

Example 1: Daily programming CH, built-in programme STD

ON1 CH

OFF1 CH

ON2 CH

OFF2 CH

ON3 CH

OFF3 CH

ON1 CH

SAVED

DAY/

PROG RUN

TIME

Set date and time

If you wish to change the date or time, follow the instructions below:

DAY

MONTH

YEAR

HOUR

MINUTE

DONE

DAY/

PROG RUN

TIME

1. Press the

SELECT

Override

HEATING

HOT WATER

Extra Hour

Mode

DAY/

CH

RUN

TIME

OFF

am

Thu

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

07 / 02 / 2013

ON1

OFF

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

ON1

DHW

Override

Extra Hour

Mode

OK

Holidays

Select

until menu DAY/TIME is selected.

Z

Z

Select indicator lamp

DAY/TIME is ON.

2. Enter day, or , and confi rm with .

Z

Z

Preset value

MONTH is fl ashing.

3. Enter month, or , and confi rm with .

Z

Z

Preset value

YEAR is fl ashing.

4. Enter year, or , and confi rm with .

Z

Z

Preset

TIME is displayed.

5. Enter hour, or , and confi rm with .

Z

Z

Preset value

MINUTE is fl ashing.

6. Enter minute, or , and confi rm with .

Z

Z

The date and time are saved.

7. Press the

SELECT

Override

HEATING

HOT WATER

Extra Hour

Mode

DAY/

CH

RUN

TIME

OFF

am

Thu

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

07 / 02 / 2013

ON1

OFF

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

ON1

DHW

Override

Extra Hour

Mode

OK

Holidays

Select

until indicator lamp RUN is ON.

1. Press the

SELECT

Override

HEATING

HOT WATER

Extra Hour

Mode

DAY/

CH

RUN

TIME

OFF

am

Thu

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

07 / 02 / 2013

ON1

OFF

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

ON1

DHW

Override

Extra Hour

Mode

OK

Holidays

Select

until indicator lamp PROG is ON.

Z

Z

Preset value ON1 (06:30) is fl ashing.

Set time:

• If you make any changes, you must press OK to confi rm ALL

ON/OFF pairs before pressing the select button to return to

the RUN mode, otherwise your changes will be lost.

• Press

or briefl y to increase/decrease the time in 1

minute steps.

Press and hold or longer than 2 seconds to increase/

decrease the time quickly.

Or press OK to confi rm a displayed (fl ashing) value

2. Enter hour and minute for the new

ON1 command, or ,

and confi rm with .

Z

Z

Preset value OFF1 (08:30) is fl ashing.

3. Enter hour and minute for the new

OFF1 command, or ,

and confi rm with .

Z

Z

Preset value ON2 (12:00) is fl ashing.

4. Enter hour and minute for the new

ON2 command, or ,

and confi rm with .

Z

Z

Preset value OFF2 (12:00) is fl ashing.

Override

Extra Hour

Mode

DAY/

PROG RUN

TIME

OK

Holidays

OFF

am

Thu

AUTO

ONCE

CONT

EXT HOUR

+1

+2

+3

07 / 02 / 2013

ON1

Select

1)

1)

A Day of the week indicator
B current day, month, year
C central heating operating

mode indicator

D central heating override

button

E central heating extra hour

button

F central heating operating

mode button

G central heating indicator lamp
H central heating extra hour

indication

I

central heating programming

period indication

J Select indicator lamps
K Select
L Ok button
M “-” and “+” button
N

1)

holiday button

O

1)

holiday icon

P Information text line
Q analog clock /

current time

R Warning icon

Display / Function keys

Commissioning

When fi rst using the timer, you have to set programming type,

date and time.

PROG TYPE

DAY

MONTH

YEAR

HOUR

MINUTE

DONE

1. connect the programmer to power.

Z

Z

Product name and version number are displayed briefl y.

Z

Z

The preset

PROGRAMMING TYPE and OK are fl ashing.

Depending on the product you can choose between three different

settings: Daily, Weekly

1)

or Week-Weekend

1)

.

Daily

all days (Monday - Sunday) are programmed

with the same ON/OFF time schedule

Weekly

1)

You can program each day (Monday, Tuesday,

...) with a different ON/OFF time schedule

Week-Weekend

1)

You can program Monday - Friday with a ON/

OFF time schedule and Saturday - Sunday with

a different one.

2. choose your desired programming type (DaIlY, WEEklY

1)

,

WEEk-WEEkEND

1)

), or , and confi rm with .

Z

Z

Preset value

DATE is fl ashing.

3. Enter day, or , and confi rm with .

Z

Z

Preset value

MONTH is fl ashing.

4. Enter month, or , and confi rm with .

Z

Z

Preset value

YEAR is fl ashing.

5. Enter year, or , and confi rm with .

Z

Z

Preset

TIME is fl ashing.

6. Enter hour, or , and confi rm with .

Z

Z

Preset value

MINUTE is fl ashing.

7. Enter minute, or , and confi rm with .

Z

Z

The date and time are saved.

Z

Z

The programmer goes to

RUN mode.

1.5 m

1)

Function not available for all products.

More information on our web page:
http://qeg.graesslin.de/qrcode/im/qeg1/

Grässlin GmbH

Bundesstraße 36

D-78112 St. Georgen

Germany
Phone: +49 7724 933-0

Fax: +49 7724 933-240
www.graesslin.de

[email protected]

80.10.1351.7/12/13/02

1. Make sure the device is working in

RUN mode.

2. Press and hold buttons at the same time for 10 seconds.

Z

Z

INST MENU opens and OK is fl ashing.

3. Confi rm with .

Z

Z

Installers menu is activated.

4. Press 3 x until

PROG TYPE is displayed.

5. Press

to edit settings.

Z

Z

Preset value is fl ashing.

6. Press

or to scroll through the menu. choose your desired

setting (DaIlY, WEEklY

1)

, 5-2 DaYS

1)

) and confi rm with .

Z

Z

The chosen setting is saved.

Z

Z

The next menu item

NR PERIODS is displayed.

NR PERIODS

DEFAULT PROG

PUMP GRAVITY

7. Press

to go to

DEFAULT PROG.

8. Press

to edit settings.

Z

Z

Preset value is fl ashing.

9. Press or to scroll through the menu. choose your desired

setting (STD, HOME or ECO) and confi rm with .

Z

Z

The chosen setting is saved

Z

Z

The next menu item

PUMP GRAVITY is displayed.

10. To save your settings, continue scrolling through the menu

options with key, until you once again see

INST MENU / –

OK +, and fi nally leave the installers menu with key.

With QEG-1S, continue scrolling through the menu options with

key, until you see

CHANGE PIN / – OK +, and fi nally leave

the installers menu with key.

Change AM/PM time display to 24 hour clock

Your programmer can operate on the 12 hour aM/PM or 24 hour clock

formats.

If you wish to change the clock format, follow the instructions below:

10 sec.

INST MENU

DIGI CLOCK

12 24 HRS

1. Make sure the device is working in

RUN mode.

2. Press and hold buttons at the same time for 10 seconds.

Z

Z

INST MENU opens and OK is fl ashing.

3. Confi rm with .

Z

Z

The menu item

DIGI CLOCK is displayed.

4. Press to edit settings.

Z

Z

Setting

NO is fl ashing.

5. Press

or to scroll through the menu. choose

YES and

confi rm with .

Z

Z

Setting

AM PM is fl ashing.

6. Press or to scroll through the menu. choose

AM PM or 24

HRS and confi rm with .

Z

Z

The chosen setting is saved.

Z

Z

The next menu item

BACKLIGHT is displayed.

7. To save your settings, continue scrolling through the menu options

with key, until you once again see

INST MENU / – OK +, and

fi nally leave the installers menu with key.

With QEG-1S, continue scrolling through the menu options with

key, until you see

CHANGE PIN / – OK +, and fi nally leave the

installers menu with key.

80.10.1351.7_manual_QEG1_QEG1S_FERTIG_V02.indd 1

24.04.2013 11:37:31

Advertising
This manual is related to the following products: