8
SERVICE HINTS:
(940530)
SYMPTOM
CAUSE
ACTION
Noise
Unbalance in VCA tube
Adjust balance
Noise
Noisy VCA tube (V1, V101)
Replace and adjust
Noise
Control amp IC 4 (IC 104)
Replace. Check gain reduction and readjust
Hum
+12V, +110V, +15V PSU
Repair
Overshoot when compressing
Unbalance in VCA tube
Adjust balance
Oscillations with no signal and
max ratio and low threshold
Unbalance in VCA tube
Adjust balance (replace tube)