Volume, Bypass, Bypass-input – Vermona Retroverb Lancet - spring reverb User Manual

Page 8

Advertising
background image

VOLUME

This control sets the output level of Retroverb Lancet.

BYPASS

Set this switch to the lower position (the red LED lights up) to disable all
sections of Retroverb Lancet. The unit offers a true bypass meaning that
the complete signal path including the input preamplification stage is
disabled. The input signal is passed directly to the output after the input
stage. With the switch set to the upper position, all sections are active.

BYPASS-Input

This TRS-jack allows connecting a single- or double footswitch to
remote-control the bypass function. Using a double footswitch allows
you to either switch the unit to bypass or to disable the spring reverb
section only.

To use the double footswitch function, the footswitch needs to be
equipped with a TRS-jack. The spring bypass uses the ring contact,
while the total bypass uses the tip contact. Connecting a TS-jack allows
switching the global bypass function only.

tip

ring

Effect Stop

True Bypass

Picture 3: Connecting a Bypass Switch

NOTE

Since this function is a switch, it does not matter whe-
ther you use a footswitch configured as being normally
closed or normally open. However, if the footswitch has
a corresponding LED, normally open configured swit-
ches will work as expected while normally closed confi-
gurations will display the status reversed.