7. Tubular heating element must be flush against

bracket (see Figure 14). This centers the ele-

ment to the center hole in metal pan.

8. Fan must be located with set screw at back of

and on flat of shaft (see Figure 15).

9. Heater is equipped with heat reflective tape.

If loose or damaged, replace tape as shown in

Figures 16 and 17. Tape edge should touch top

of louver openings.

REASSEMBLY POINTS

Continued

Figure 14 - Heating Element and Bracket

Figure 15 - Fan and Motor

Figure 16 - Reflective Tape and Louvers

Figure 17 - Reflective Tape on All Louvers