SAFETY INFORMATION

Continued

29. Use only in accordance with the local ordi-

nances and codes.

30. This product is not to be used as the sole

support for an umbrella. Umbrella must be

supported by a table.

31. Do not use or install umbrella into product

at temperatures below freezing. A damaged

product could result in the risk of fire, electric

shock and injury to persons.

32. Do not use this at any elevation above floor

level. Do not place on a table.

33. Locate product so “ON” light can be easily seen

10 ft (3.05 m) around and 5 ft (1.52 m) above.

34. If a table cloth is used on the table above the prod-

uct, secure it to prevent movement due to wind.

35. Do not use in temperatures above 75° F

(28.9° C). Nuisance tripping of manual reset

thermal protector can occur.

36. Take precautions to prevent spilling drinks on

product.

37. If the product will not operate, see specific

instructions in Troubleshooting, page 6.

38. Save these instructions for future reference.

This product contains and/or

generates chemicals known to

the state of California to cause

cancer or birth defects or other

reproductive harm.

PRE-OPERATING

INSTRUCTIONS

GROUND FAULT INTERRUPTER

• Since 1971 the National Electric Code (NEC)

has required Ground Fault Circuit Interrupter

devices on all outdoor circuits.

• If your residence was built before 1971, check with

a qualified electrician to determine if a Ground

Fault Circuit Interrupter protector exists.

• Do not use this product if the circuit does not

have a GFCI protection.

• Do not plug this product into an indoor circuit.
• Typical accepted GFCI devices are shown in

Figure 1.

• Avoid the use of an extension cord. Extension

cord may overheat and cause risk of fire. If you

must have an extension cord, the cord shall be

minimum size of 14 awg and not rated less than

1875 watts. Use only 3 wire cord type (3 prong

plug) marked for outdoor use.

PLUG ADAPTER

IMPORTANT:

This product must be used on a

grounded supply circuit.
An adapter as shown in Figure 2 is available for

connecting three-prong grounding type plugs to

two-slot receptacles. The green grounding lug

extending from the adapter must be connected to

a permanent ground such as a properly grounded

outlet box.

Figure 2 - Plug Adapter

Metal
Screw

Cover of
Grounded
Outlet Box

RESET

TEST

WARNING

Test and
Reset
Buttons

GFCI Cord
Adapter

Figure 1 - GFCI Options