1. Disconnect the power cord from the branch

circuit mains.

2. Remove bottom cover from power head.

Remove four (4) hex head screws from front

and rear covers.

Slide bottom cover off.

3. Remove existing power cord from power head.

Disconnect three power cord wires.

Remove and discard power cord.

Remove 7/8

diameter knock-out plug.

Install a suitable entrance bushing.

4. Install permanent wiring to power head.

For Stealth—connect permanent wiring to

internal terminal block.

Connect white supply line to silver terminal.

Connect black supply line to brass terminal.

Connect ground wire to green wire location

(GROUND).

For ProMax—connect permanent wiring.

Make connections with UL recognized wire nuts.

Connect white supply line to white wire.

Connect black supply line to black wire.

Connect ground wire to green wire location

(GROUND).

Wires inside operator are to be a minimum of

6 inches.

5. Replace power head bottom cover.

Replace and tighten four (4) hex head screws.

NNOOTTEE:::: CCiirrccccuuiitttt bbbbooaarrrddddsss aarree llliiggghhhhttt sseennssiiiittiivvee.. MMaakkkkee ssuurrrreeee

ccoovveerr iissss oonn ppoowweeeerr hheeaaaadd bbeeffffooorrreeee ooooppppeerraaaattiioooonnnn..

1. Check local building codes.

Some building codes require direct wiring to a

branch circuit. If direct wiring is NOT required,

plug door operator into grounded outlet

(Fig. 6-1)

.

2. Return to Section 3 for SAFE-T-BEAM

®

System

alignment and troubleshooting.

NNOOTTEE::: IIffff ppppeeeerrmmaannnneeeenntt wwiirrrriiiinngg iiss rreeqquuiirrrreeeedd,, hhhaaavvee aaa

pprrooffeessssssiioooonnnnaaaall eelleeccccttrriicciiiiaann iinnnnssssttaallllll cciirrrrcccuuiittt aannnddd wwiirrreeee

ddoooorr ooppeerraattoorr...

Fig. 5-1

Operator

power cord

Grounded

outlet

To reduce the risk of electrical shock, this equipment

has a grounding type plug that has a third

(grounding) pin.This plug will only fit into a grounding

type outlet. If the plug does not fit into the outlet,

contact a qualified electrician to install the proper

outlet. Do Not change the plug in any way.The door

operator must be properly grounded to prevent

personal injury and damage to the components.

The ELECTRICAL POWER to the door operator

MUST BE TURNED OFF when power head cover is

removed. Electrical power must remain off while mak-

ing electrical

connections.

55

.......

CCOONNNNNEECCCTTTT OOOOPPEEEERRAATTOORRR TTOOOO PPPPOOWWWWEEEERR

FFOOR HELLP--1.8000.3354.36443 OOR GGENIECOMPANY.COM