1. GENERAL INSPECTION – Examine the furnace installation

for the following items:

a. All flue product carrying areas external to the furnace

(i.e. chimney, vent connector) are clear and free of
obstruction.

b. The vent connector is in place, slopes upward and is

physically sound without holes or excessive corrosion.

c. The return air duct connection(s) is physically sound, is

sealed to the furnace and terminates outside the space
containing the furnace.

d. The physical support of the furnace should be sound

without sagging, cracks, gaps, etc., around the base so
as to provide a seal between the support and the base.

e. There are no obvious signs of deterioration of the

furnace.

f. The burner flames are in good adjustment without

erratic flames. See illustration below.

g. Fresh air inlet and vent are not blocked and free from

obstruction. The horizontal or vertical vent and inlet
must be located at least 12 inches minimum (18 inches
in Canada) above the normally expected snow
accumulation level.

Contact your service agent if you feel you are uncomfortable
performing any of the inspections noted in section 1.
2. BLOWERS – The blower size and speed determine

the air volume delivered by the furnace. The blower
motor bearings are factory lubricated and under normal
operating conditions usually do not require servicing.
Annual cleaning of the blower wheel and housing is
recommended for maximum air output, and this must be
performed only by a qualified servicer or service agency.

3. IGNITER – This unit has a special hot surface direct ignition

device that automatically lights the burners. Please note
that it is very fragile and should be handled with care.

For regular dealer maintenance please refer to
www.acca.org/industry/quality
To ensure proper operation of your furnace, the
recommended dealer inspection is once a year, before the
heating season. Regular maintenance must be performed by
a qualified service professional.
The servicer should perform steps 1–9 once a year before
the heating season.
The homeowner should perform the visual inspection in step
1 monthly when cleaning the furnace filter.
Unless it is an emergency, never stop the heating system by
shutting off the main power.
If the main power to your air conditioner is ever disconnected
for more than three hours, turn off the thermostat. Then wait
for at least three more hours after the power has been restored
before turning the thermostat back on. Failure to follow this
procedure could result in damage to your furnace.

Regular Dealer Maintenance

The following warning complies with State of California law, Proposition 65.

HAZARDOUS GASES
Exposure to fuel substances or by-products of incomplete

fuel combustion is believed by the state of California to cause

cancer, birth defects, or other reproductive harm.

HAZARDOUS GASES
Unit is equipped with a blower door switch which cuts power

to blower and gas valve causing shutdown when door is

removed. Unit must not be altered to allow operation with the

blower door removed. Operation with doors removed or ajar

can permit the escape of dangerous fumes. All panels must be

securely closed at all times for safe operation of the furnace.

Failure to follow this warning could result in property damage,

personal injury or death.

EXPLOSION HAZARD
In the event that electrical, fuel or mechanical failures occur,

SHUT off the gas supply at the manual gas SHUT OFF valve,

located ON THE SUPPLY GAS PIPING COMING INTO THE

FURNACE, BEFORE TURNING OFF THE electrical power to the

furnace. contact servicer.
Failure to follow this warning could result in property damage,

personal injury or death.

Do NOT touch igniter. It is extremely hot.

EXPLOSION HAZARD
Should overheating occur, or the gas supply fail to shut off, shut

off the manual gas valve to the furnace before shutting off the

electrical supply.
Failure to follow this warning could result in property damage,

personal injury or death.