Danby DPAC8399 User Manual

Page 9

Advertising
background image

CLOCK: Allows you to initiate and/or change the
TIME OF DAY setting.

TIMER ON: Used to initiate the AUTO ON start time
program, in conjuction with the & key pads.

TIMER OFF: Used to initiate the AUTO OFF stop
time program, in conjuction with the & key
pads.

Fig. 5

Fig. 6

Green light while cooling.

Red light while heating.

Green light while dehumidifying.

Fig. 7

A warning signal of 8 beeps will sound and

the Water Full indicator will flash every

0.5 seconds.

Key Pad Functions

Fig. 5

The control panel on this unit “illuminates”
automatically when any key pad is depressed. This
“illumination” feature will “self-deactivate” (turn-off)
automatically approx. 30 seconds after the last key
pad is depressed.

I/O: Power Switch On / Off.

MODEIndicator Lights: Illuminate under the

different mode settings

Fig. 6;

COOL Mode:

Green Light

DRY (Dehumidifier) Mode:

Green Light

HEAT Mode:

Red Light

FAN Mode:

No indicator light

Green Light: Remains on while compressor is

operating. Green light turns off when desired
temperature is achieved. Applicable to both Air
Conditioner and Dehumidifier.

Red Light: Remains on while heater is

operating. Red light turns off when desired temperature
is achieved.

Water Full Indicator Light: Flashes red when

the water level of the water tank exceeds the maximum
set level or if the water tank is not correctly positioned in
the cabinet.

Fig. 7.

FAN: Selects Low-Medium-High fan speeds.

Fan Options:

Cooling (3 speeds) Low-Medium-High
Heating (2 speeds) Low-High
Dry - Dehumidifying (1 speed) Medium.
Fan (3 speeds) Low-Medium-High

Temp/Clock Adjustments:

: Used to adjust (forward) Time of Day Clock settings (1

min. increments).
Used to adjust (forward) Temperature settings (1°C
increments).
Used to adjust (forward) Temperature settings (2°F
increments).
Used to adjust (forward) Auto-Timer settings
(10 min. increments)

: Used to adjust (backward) Time of Day Clock settings

(1 min. increments).
Used to adjust (backward) Temperature settings (1°C
increments).
Used to adjust (backward) Temperature settings (2°F
increments).
Used to adjust (backward) Auto-Timer settings (10 min.
increments)

SWING: Allows the vertical louver grills to oscillate

back and forth automatically (70° Swing).

Temperature Conversion Chart

°C

10

11

12

13

14

15

16

17

18

19

20

21

°F

50

52

54

55

57

59

61

63

64

66

68

70

°C

22

23

24

25

26

27

28

29

30

31

32

33

°F

72

73

75

77

79

81

82

84

86

88

90

91

NOTE: This appliance provides a feature that will allow you the
option of setting “temperatures” in “Celsius” or “Fahrenheit”.
To change the temperature display on the main unit, press the
(Temp/Clock) “ “ keypad & “Clock” keypad “simultaneously”
to alternate between the˚C & ˚F scale
Celisus scale allows adjustments in 1˚C increments.
Farenheight scale allows adjustments in 2˚F increments.

Graduación del RELOJ DE ENCENDIDO
AUTOMÁTICO (continúa)

5) Ahora se han registrado todas las graduaciones. APAGUE LA

UNIDAD USANDO ELCONMUTADOR I/O.

6) Para graduar el reloj de ENCENDIDO AUTOMÁTICO, la unidad

deberá estar en la posición “off” (apagada) o sea no funcionando.

7) Oprima la tecla de TIMER-ON (RELOJ DE ENCENDIDO

AUTOMÁTICO) para iniciar la secuencia de tiempo de
ENCENDIDO AUTOMÁTICO.

Figura 32

. La ventana de

visualización indicará TIMER ON y la palabra ON (ENCENDIDO)
centelleará durante 5 segundos. Oprima la tecla o para
seleccionar la hora deseada de encendido automático.

Figura 32a.

La tecla disminuirá la graduación del horario automático en

incrementos de 10 minutos.

La tecla aumentará la graduación del horario automático en

incrementos de 10 minutos.
Cuando haya establecido el horario deseado (la hora centelleará
en la ventana de visualización) oprima la tecla CLOCK (RELOJ)
para registrar el programa de RELOJ DE ENCENDIDO
AUTOMÁTICO. La palabra ON dejará de centellear y
permanecerá encendida (RELOJ DE ENCENDIDO
AUTOMÁTICO) indicando que se ha graduado el programa. La
graduación del reloj de la hora del día regresará inmediatamente a
la ventana de visualización.

IMPORTANTE: La hora deseada para el RELOJ DE ENCENDIDO
AUTOMÁTICO se debe registrar dentro de un período de 5
segundos (después de oprimir la tecla TIMER-ON) ya que de lo
contrario la hora seleccionada no quedará registrada y el
sistema regresará automáticamente a la graduación corriente
del reloj de la hora del día. Si esto sucede, se deberá repetir el
paso número 7.

La unidad se encenderá automáticamente cuando el reloj de la hora
del día indique la hora de ENCENDIDO AUTOMÁTICO especificada
(la señal de TIMER ON desaparecerá de la ventana de visualización).
Para cancelar o reemplazar el programa de RELOJ DE ENCENDIDO
AUTOMÁTICO, simplemente encienda la unidad antes de la hora en
que el ENCENDIDO AUTOMÁTICO está programado para funcionar
(la señal de TIMER ON desaparecerá de la ventana de visualización).

Se puede verificar la hora seleccionada para ENCENDIDO
AUTOMÁTICO en cualquier momento (antes de que se inicie el
programa), simplemente oprimiendo la tecla de TIMER ON. La hora
seleccionada aparecerá (centelleará) provisoriamente (reemplazando
la hora del día) por unos 5 segundos.

Fig. 32

Fig. 32a