Installing 9-Volt Battery in Hand-Held Remote
Control Unit

1.

Remove battery cover on back of remote control unit.

2.

Attach terminal wires to the battery (not included). Place bat-
tery into the battery housing.

Note:

Only use alkaline battery.

3.

Replace battery cover onto remote control unit.

Figure 17 - Installing Battery in Hand-Held Remote Control Unit

Battery
Cover

9-Volt
Battery

Terminal
Wires

Remote
Control Unit

Battery
Housing

Figure 16 - Installing Battery in Receiver

Battery
Clip

9-Volt Battery

Receiver

Terminal
Wires

INSTALLATION

Continued

4.

Connect wires to control circuit. Connect white wire to termi-
nal marked TH/TP on control valve. Connect red wire to male
blade connector provided at open end of safety circuit wiring
(see Wiring Diagram, page 20).

5.

Locate the battery clip mounted on the back of the receiver
(see Figure 16).

6.

Slide 9-volt battery (not included) through the clip.

Note:

Only

use alkaline battery.

7.

Attach the terminal wires to the battery (see Figure 16).

8.

Replace refractory brick access panel.

GAS LINE HOOK-UP

Figure 18 - Manual Shutoff Valve Installation

Figure 19 - Routing Incoming Gas Line

WARNING: Gas line hookup should be done by

your gas supplier or a qualified service person.

WARNING: Before you proceed, make sure your

gas supply is OFF.

Typical Exterior Wall Gas
Shutoff Installation

CAUTION: Do not kink flexible gas line.

A manual shutoff valve has been included in the appliance’s gas
supply system. You may consider installing an extra gas shutoff
valve outside the appliance’s enclosure (check with local codes)
where it can be accessed more conveniently with a key through a
wall as shown in Figure 18.

In conformance with local codes, route a 1/2" NPT gas line
towards the appliance coming in from any of the 3 directions
shown in Figure 19.

Key

Extension

Shutoff
Valve

A

B

1/2" NPT Incoming
Black Iron Gas Line

Flexible Gas Line
(1 Provided) Can
Be Extended Out
Either Side

7"

7"

Alternate Gas Supply
Through Sub-Floor

M36(B,H)/VM36(B,H)

M42(B,H)/VM42(B,H)

A

8

5

/

8

" (219mm)

10

1

/

2

" (267mm)

B

11" (279mm)

12

3

/

4

" (324mm)

INSTALLATION

Optional Wireless Hand-Held Remote Control Installation (Cont.)
Gas Line Hook-Up

Advertising