Inspecting heater, Operating heater – Desa VSF30PT User Manual

Page 14

Advertising
background image

www.desatech.com

116307-01C

14

OPERATING HEATER

Continued

If pilot flame pattern is incorrect, as shown in

Figure 19

• turn heater off (see To Turn Off Gas to Ap-

pliance, page 13)

• see Troubleshooting, page 16
Note:

The pilot flame on natural gas units will

have a slight curve, but flame should be blue and

have no yellow or orange color.

Figure 19 - Incorrect Pilot Flame Pattern

Figure 18 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

Pilot Burner

Thermocouple

Blue Pilot Flame

Yellow Pilot Flame

BURNER FLAME PATTERN

WARNING: If yellow tipping

occurs, your heater could pro-

duce increased levels of carbon

monoxide.

NOTICE: Do not mistake orange

flames with yellow tipping. Dirt

or other fine particles enter the

heater and burn causing brief

patches of orange flame.

THERMOSTAT cONTROL

OPERATION

The thermostatic control used on these models

differs from standard thermostats. Standard

thermostats simply turn on and off the burner.

The thermostat used on this heater senses the

room temperature. At times the room may

exceed the set temperature. If so, the burner

will shut off. The burner will cycle back on

when room temperature drops below the set

temperature. The control knob can be set to

any heat level between 1 and 5.

T

his adjusts the

amount of gas flow to the burner that increases

or decreases the burner flame height.
Note:

The thermostat sensing bulb measures

the temperature of air near the heater cabinet.

This may not always agree with room tem-

perature (depending on housing construction,

installation location, room size, open air tem-

peratures, etc.) Frequent use of your heater will

let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1. Remove front panel (see Figure 10, page 9).

2. Follow steps 1 through 7 under Lighting

Instructions, page 13.

3. With control knob pressed in, strike match.

Hold match to pilot until pilot lights.

4. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Now follow step 9, under

Lighting Instructions, page 13.

5. Replace front panel.

INSPECTING HEATER

Check pilot flame pattern and burner flame pat-

tern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pattern. Figure

19 shows an incorrect pilot flame pattern. The incor-

rect pilot flame is not touching the thermocouple.

This will cause the thermocouple to cool. When the

thermocouple cools, the heater will shut down.

Advertising
This manual is related to the following products: