The gas connection to the appliance is effected by means of a suitable
coupling tube fitting L8, DIN 2353-ST, complying with European Standard
EN 1949 (e.g. Ermeto).

The gas connection may only be carried out by a qualified personnel.

Following proper installation, a testing for
leakage and a flame test must be carried
out by *qualified personnel in compliance
with EN1949 .

A certificate of testing must be issued.

* qualified personnel

Qualified personnel are accredited experts who
are able, by virtue of their training and knowledge,
to vouch for the correct implementation of the lea-
kage test.

The refrigerator must be equipped with a
gas cock (C) in the supply line to allow the
supply to be disconnected. Such a cutout
device must be readily accessible to the user.

SW 14

SW 17

C

Gas pressure

Category I

3P(30)

I

3P(37)

I

3P(50)

I

3+

I

3B/P(50)

I

3B/P(30)

mbar 30

37

50

28-37

30-37

50

30

BE

•

DK

•

DE

•

•

FI

•

FR

•

GR

•

•

IE

•

•

IS

•

IT

•

LU

•

•

NL

•

•

NO

•

AT

•

•

PT

•

•

SE

•

CH

•

•

ES

•

UK

•

•

•