Function description

Operating Manual PIT m3.2p
1003176­EN­02

32

4.3.3

Evaluation by a control system

4.3.3.1

Evaluation of the Key ID number with transmitter­controlled communication

IDo0

(IDsync)

Bit 27

Bit 25

… Bit 16

Bit 15

Bit 14

IDo2

(IDout0)

Bit 26

[c]

[d]

t

en

IDo1

(IDclock)

[b]

max. 100 ms

Bit 13

Bit 11

… Bit 02

Bit 11

Bit 00

IDo3

(IDout1)

Bit 12

Bit 27

Bit 25

… Bit 16

Bit 15

Bit 14

IDi0

(IDin0)

Bit 26

Bit 13

Bit 11

… Bit 02

Bit 11

Bit 00

IDi1

(IDin1)

Bit 12

T

[a]

min. 60 ms

[f]

[e]

Fig.: Timing diagram for transmitter­controlled signal download

Legend:

The additional terminal designations (IDsync, IDclock, IDout0 etc.) are abbreviations for
the terminal signal's application.

IDo0

Control line 
The signal is generated by the operating mode selector switch.

"0" signal

No transponder key is connected or the transponder key that
is connected is invalid.

"1" signal

A valid transponder key is created. The operating mode se­
lector switch signals to the control system when the down­
load starts. The signal is present for 100 ms.

IDo1

Test pulse line 
The signal is generated by the operating mode selector switch and indic­
ates the validity of the data bits at IDo2 and IDo3.

}

T = 100 ms

}

Duty cycle = 50%

IDo2, IDo3

Data lines for transmitting the Key ID number
The operating mode selector switch sends the Key ID number to the con­
trol system via these two data lines.

IDo2:

Send Bit 27 … Bit 14

IDo3

Send Bit 13 … Bit 00

IDi0, IDi1

Data line for reading back the Key ID number
The control system sends the previously received Key ID number back to
the operating mode selector switch via these two data lines.

IDi0:

Receive Bit 27 … Bit 14

IDi1

Receive Bit 13 … Bit 00