Nexen DFC-1650 964149 User Manual
Page 8

8
FORM NO. L-20312-C-0110
FRICTION FACING INSPECTION
Visually inspect the Friction Facings after every forty hours of
operation. Replace the friction facings when the remaining
material is 5/16" thick. Use a scale to measure the thickness
on the DFC-2200.
The DFC-1650 has steps in the friction facing which
indicate 5/16" thickness. When the steps are no longer
visible, the facings need to be replaced (See Figure 7).
FIGURE 7
Steps in
Friction Facings
WARNING
Never exceed maximum operating
speeds listed for your product.
(See Table 1).
OPERATION
TABLE 1
Size
Max RPM
DFC 1650
1,200
DFC 2200
900
CAUTION
The temperature limits for this
product line are 4.5-104 Degree
Celsius (40-220 Degree F).
WARNING
Ensure proper guarding of the product is used.
Nexen recommends the machine builder
design guarding in compliance with OSHA 29
CFR 1910 “Occupational Safety and Health
Hazards”.
CAUTION
Never exceed life of facing material. Facing
life depends on the volume of material and
the total energy over the life of the unit.
Expected life (in hrs) can be found by:
Time=Volume/(Power*Wear Rate).