Nexen S-450 827801 User Manual
Page 6

FORM NO. L-20087-P-1112
6
AIR CONNECTIONS
The following is a common air supplied scheme used with
this product. This is an example and not an all-inclusive
list. All air circuits to be used with this product must be
designed following EN983 guidelines.
CAUTION
Low air pressure will cause slippage and
overheating. Excessive air pressure will
cause abrupt starts and stops, reducing
product life.
All Nexen pneumatically actuated devices require clean
and dry air, which meet or exceeds ISO 8573.1:2001
Class 4.4.3 quality.
NOTE
Note: Nexen pneumatically actuated devices require clean, pressure regulated air for maximum performance
and life. All seals in Nexen pneumatically operated devices are lubricated for life, and do not require additional
lubrication.
However, some customers prefer to use an air line lubricator, which injects oil into the pressurized air, forcing
an oil mist into the air chamber. This is acceptable, but care must be taken to ensure once an air mist lubrication
system is used, it is continually used over the life of the product as the oil mist may wash free the factory
installed lubrication.
Locate the lubricator above and within ten feet of the product, and use low viscosity oil such as SAE-10.
Synthetic lubricants are not recommended.
Nexen product's bearings are shielded and pre-lubricated, and require no further lubrication.
LUBRICATOR DRIP RATE SETTINGS
1. Close and disconnect the air line from the unit.
2. Turn the Lubricator Adjustment Knob counterclockwise three
complete turns.
3. Open the air line.
4. Close the air line to the unit when a drop of oil forms in the
Lubricator Sight Gage.
5. Connect the air line to the unit.
6. Turn the Lubricator Adjustment Knob clockwise until
closed.
7. Turn the Lubricator Adjustment Knob counterclockwise one-
third turn.
8. Open the air line to the unit.
LUBRICATION
CAUTION
These settings are for Nexen supplied
lubricators. If you are not using a Nexen
lubricator, calibration must follow the
manufacturer's suggested procedure.
Note
For quick response, Nexen recommends a quick exhaust
valve and short air lines between the Control Valves and
the unit. Align the air inlet ports to a down position to
allow condensation to drain out of the air chambers of
the product.
- S-450 827800 S-450 827812 S-450 827803 S-450 827804 S-450 827805 S-450 827808 S-450 827806 S-450 827807 S-450 827824 S-450 827814 S-450 827826 S-450 827828 S-450 827811 S-450 827809 S-450 827817 S-450 827823 S-450 827810 S-450 827829 S-450 827822 S-450 827830 S-450 827815 S-450 827816 S-600 827914 S-600 827901 S-600 827903 S-600 827900 S-600 827925 S-600 827928 S-600 827906 S-600 827902 S-600 827919 S-600 827911 S-600 827913 S-600 827915 S-600 827910 S-600 827916 S-600 827917 S-600 827912 S-600 827918 S-800 828000 S-800 828014 S-800 828003 S-800 828020 S-800 828004 S-800 828002 S-800 828001 S-800 828019 S-800 828012 S-800 828022 S-800 828021 S-800 828005 S-800 828009 S-800 828015 S-800 828016 S-800 828018 S-800 828010 S-800 828017 S-800 828031 S-1000 828101 S-1000 828100 S-1000 828112 S-1000 828113 S-1000 828104 S-1000 828103 S-1000 828116 S-1000 828118 S-1000 828107 S-1000 828190 S-1000 828114 S-1000 828119 S-1000 828111 S-1000 828191 S-1000 828115 S-1000 828117 S-1000 828192 S-1000 828110 S-450A 827821 S-450A 827820 S-450A 827827 S-450A 827819 S-450A 827818 S-600A 827908 S-600A 827907 S-800A 828029 S-800A 828008 S-800A 828023 S-600A 827926 S-600A 827905 S-600A 827904 S-600A 827927 S-600A 827921 S-600A 827922 S-600A 827923 S-600A 827924 S-600A 827909 S-800A 828006 S-800A 828007 S-800A 828026 S-800A 828025 S-800A 828032 S-1000A 828122 S-1000A 828121 S-1000A 828126 S-1000A 828108 S-1000A 828109